and several operators
stand. ControlBuilderF engineering station configures and adjusts the system
Mode. Usually, we can use portable devices such as notebooks to
The system is now configured in the office and on site. Operator-level PC
Can also be used as an engineer station. Engineer standing during system uptime
Intervals can be closed without a permanent connection to the system.
Freelance 800F Process Control Stage
At the process control level, the Freelance 800F system can be controlled by
It consists of a number of process control stations connected to I/O units. you can choose this
Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy
redundant) or non-redundant mode. Modular pluggable input/output modules
Blocks are freely selected and used according to the type and number of system process signals.
AC800F controller connects remote I/O or field device via fieldbus
ready.
system communication
Communication between operator level and process control level using TCP/IP
Protocol system bus (based on Ethernet), you can choose different
transmission medium such as AUI, twisted pair, fiber optic or coaxial cable.
Freelance OPC server for connecting to higher-level operators
station (800xA) or other OPC client. Freelance Control System
Real-time process values ??and alarms in the system can be accessed via OPC.
We also provide a C language programming interface to embed external
In Windows operating system applications, it is suitable for implementing user
Communicate with non-standard OPC, ie DMS-API software package.
Project database
All configured signals, variables and process points are in Freelance
800F system’s public database for management.
● List of all variables (input, output, internal variables)
● Process point list (function block)
●Graphics
●Program
Because the database is system-wide. The data only needs to enter a
times, to avoid possible errors caused by multiple configurations.
Project database files can be easily archived or backed up.
When programmed by the user, a list of variables and labels is automatically created.
Moreover, both variables and process points can be opened and closed directly in FBD or IL
Revise.
List other features include:
Project-wide modification of names, comments, data or module types
●Search and display based on specific criteria
● Cross reference can be used in systems that use a large number of variables or process points
Programs and drawings to quickly find the desired variable or process point within the scope
noodle.
ABB is the world’s largest in measurement and process automation
One of the equipment and system suppliers.
An important factor in maintaining this market position is the quality of our products
quantity, and quality from manufacture all the way to service. ABB automation early
In 1990, it obtained the DQS certificate based on ISO9001 certification,
EQnet quality based on ISO 9000/EN 29000 was subsequently achieved
Certification.
However, the Freelance 800F is more than technical excellence, I
We have also spent a lot of effort in proper planning, installation and revision too
This makes engineering design and maintenance faster, more economical and more efficient.
Industrial” is a world-leading all-round integrated open control system launched by ABB Group Automation Headquarters.
It