IS215UCVEH2A
IS215UCVEH2A
IS215UCVEH2A
the system can also use the public telephone network (dial-up mode) or satellite to achieve ultra-long-distance communication.
Subsystems such as PLC communicate with the Industrial” system through the ModBus protocol interface. The system also supports IEC870-5 over-control protocol.
discussion.
The Flash EPROM inside the PS provides more than 220 functional modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard
In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control
The scheme can be realized by the combination of these function blocks.
The function blocks provided by the system mainly include the following categories:
o
Analog processing
o
digital processing
loop regulation
Logical sequence control
c
logic operation
Monitoring function
Collection function.
c
arithmetic operations
c
TCP/IP protocol communication interface
Modbus protocol communication interface
1EC870-5 protocol communication interface (Telecontrol)
4.2 Field Controller PS
Industrial” field controller PS is a special process control station, which is embedded with field bus communication interface for users to use
Fieldbus technology offers very flexible options. Each PS allows to insert 4 fieldbus interface cards (the card type can be different),
Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and play
(Plug & Play), and can be plugged and unplugged.
The field controller PS has the following characteristics:
o
Flexible: supports all international standard open fieldbuses and can be mixed
Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd)
Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software
mouth
Access to all information from the field including equipment management information
Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage systems
Module identification with production operating parameters
c
complete self-diagnosis
Compact and robust design
Front Panel Wiring
DIN rail (U-shaped) installation well can be directly wall mounted, simple and convenient
o
Allowable operating ambient temperature…60 C, with automatic temperature monitoring
o
EMC (Electromagnetic Compatibility) acco
rding to EN50082
mouth
Certifications: CE, NAMUR, CSA, CSA-NRT
Glossary
Process station:
This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant
configuration and non-redundant configuration.
AC800F :
This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2
AC800F controller.
Rack mounted process station:
This term is used to describe a rack-mounted type of process station. A redundant process station contains 2 rack-mounted CPUs.
This term is used to describe a single, non-redundant process station.
In the investment of modern automation system, due to the hardware equipment department
It only takes up less cost in the whole system, then write engineering applications
The cost of software becomes increasingly important. Generally speaking, a self
The engineering application software cost of the automation project accounts for about the entire project.
About 50%, it is not difficult to see that the