XCOM 4150

XCOM 4150 and a CPU motherboard. It periodically scans the data from the The signals of the field bus sensors are processed according to the control application program configured by the user, and then the calculation results are passed The fieldbus interface card returns the corresponding fieldbus actuator. Two field controllers can realize controller 1:1…

XYCOM 3515

XYCOM 3515 and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o  Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the…

XYCOM 3510

XYCOM 3510 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media)…

XYCOM 3115

XYCOM 3115 (IL), sequential function diagram (SFC), structured text (st) and other graphical configuration modes. The system contains about 220 functions The algorithm library of energy block, the basic library with more than 200 graphic symbols and the extended library with a large number of 3D symbols. The system uses the same set of configuration…

XYCOM 2060

XYCOM 2060 also complete system hardware diagnosis and data exchange between different systems Yes. The process control level realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between the controller and various…

XYCOM 2050

XYCOM 2050 data exchange between different systems. can. The process control stage realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control. Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between the controller and various intelligent devices such as I/0 or…

XYCOM 2005

XYCOM 2005 Freelance 800F is more than technical excellence, I We have also spent a lot of effort in proper planning, installation and revision too This makes engineering design and maintenance faster, more economical and more efficient. Industrial” is a world-leading all-round integrated open control system launched by ABB Group Automation Headquarters. It integrates the…

XYCOM 2000

XYCOM 2000 stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field device via fieldbus ready.   system communication Communication between operator level and…

XYCOM 1840

XYCOM 1840 control stations, operator stations to intelligent field devices, including Including the integrity and consistency check of the user program. ●The programming language strictly complies with the international standard of IEC61131-3, and has There are high-performance graphics editing functions: – Function Block Diagram (FBD) -Ladder Diagram (LD) – Instruction List (IL) – Sequence Control…

XYCOM 1300HAZ

XYCOM 1300HAZ Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F…