JANCD-EW01

system. ●Provide system-wide unified inspection of user applications, overriding from process control stations, operator stations to intelligent field devices, including Including the integrity and consistency check of the user program. ●The programming language strictly complies with the international standard of IEC61131-3, and has There are high-performance graphics editing functions: – Function Block Diagram (FBD) -Ladder…

JANCV-MCP02B

application software cost of the automation project accounts for about the entire project. About 50%, it is not difficult to see that the migration of cost structure creates a lot of innovation for users. Create an opportunity to optimize project investment, therefore, it is necessary to start from engineering programming Think about lowering costs in…

JANCD-GIO01B

can be directly wall mounted, simple and convenient o Allowable operating ambient temperature…60 C, with automatic temperature monitoring o EMC (Electromagnetic Compatibility) according to EN50082 mouth Certifications: CE, NAMUR, CSA, CSA-NRT Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be…

JANCD-FC900B

PS is a special process control station, which is embedded with field bus communication interface for users to use Fieldbus technology offers very flexible options. Each PS allows to insert 4 fieldbus interface cards (the card type can be different), Each card is connected to 1 field bus to collect process data and diagnostic information…

JANCD-GC26

engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables and mixed media) and network topology can be selected for the system bus. Simple layout, due to the use of TCP/IP protocol, the system can also use the public telephone network…

JANCD-SVO2C

standards and is CE marked Chi. Industrial” DCS system design purpose: the most economical engineering investment, the most powerful control function. Five features of Industria1″ DCS system: 1. All-round integrated control system, integrating DCS & PLC & Field Bus; 2. Using RISC SuperScalar high-speed CPU, with super performance; Three high reliability, strict industrial application practice,…

JANCD-NCP30

system’s Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance. System engineering is very convenient. The configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram (LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration…

JANCD-MM138

connect industrial ial “conventional process control station The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured -Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly.…

JANCD-MCP

(PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other Redundant basic…

JANCD-GFL01

check and correction function, abb patent) 16 K internal cache (CPU cache RAM) Ram backup battery (matchdog, optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point…