TRICONEX TRICON 3481

the configuration and debugging of process level, operation level and even fieldbus instruments, and uses the same a global database. The scale of the system is highly scalable, and a single-system supports 1 to a maximum of 100 control stations and 100 operating stations. each control The station can support several thousand I/0 points at…

TRICONEX TRICON 3201

topology according to the actual situation of the application. The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform. tower. The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform…

TRICONEX TRICON 3101

signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured -Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly. S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus…

TRICONEX TRICON 5481

(separated between each other Redundant basic unit pm802f) and can be plugged in and out and replaced online. Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd One PS can plug in 4 fieldbus interfaces, connect 496 fieldbus devices, and one…

TRICONEX TRICON 5451

(processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard) Interface.   Basic characteristics: 1ee802.3 Ethernet standard o Ei801f provides 10base2 thin cable communication interface Ei802f…

TRICONEX TRICON 5402

installed on the Ethernet network card or battery card The backup battery can maintain the configuration content and data in case of power failure. Basic unit pmbo2f characteristics: mouth Installation slots of 4 fieldbus interface cards c Installation slot of 2 Ethernet network cards Support redundant operation of Fieldbus interface card Support hot plug of…

TRICONEX TRICON 5401

the user, and then the calculation results are passed The fieldbus interface card returns the corresponding fieldbus actuator. Two field controllers can realize controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the…

TRICONEX TRICON 5301

standards: Profibus DP,up to 12 MBd Modbus RTU,1200 to 38. 4KBd Industrial” CAN I/0 Bus o Open CAN -Bus,up to 1 MBd o Foundation Fieldbus H1 up to 31. 25KBd Foundation Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller…

TRICONEX TRICON 5382

diagnostic information from the bus. The interface card is easy to replace and plug and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected…

TRICONEX TRICON 5381

through Modbus protocol interface. The system also supports iec870-5 over control coordination Discussion.   The flash EPROM inside PS provides more than 220 function modules (control algorithm subroutines), in addition to the base specified in IEC 61131 3 standard In addition to this content, many powerful and strictly tested function blocks from practical engineering applications…