G761-3602

language strictly complies with the international standard of IEC61131-3, and has There are high-performance graphics editing functions: – Function Block Diagram (FBD) -Ladder Diagram (LD) – Instruction List (IL) – Sequence Control Chart (SFC) . Structured Text (ST) ●Extensive function block library, user-defined function blocks can also be added Added to it, the macro library…

G761-3009A

this way, cost efficiency can be improved by reducing user engineering costs. How the Freelance 800F process control system helps users reduce Low engineering cost? ●By using a complete engineering tool (Control Builder F) to configure the entire control system, including automation functions function, operator interface display and logging, and configuration of the fieldbus. equipment…

G761-3003-5

controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack mounted process station: This term is used to describe a rack-mounted type…

G631-3006B

allows to insert 4 fieldbus interface cards (the card type can be different), Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and play (Plug & Play), and can be plugged and unplugged. The field controller PS…

G631-3004B

as PLC communicate with the Industrial” system through the ModBus protocol interface. The system also supports IEC870-5 over-control protocol. discussion. The Flash EPROM inside the PS provides more than 220 functional modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard In addition to this content, many powerful…

G631-3002B

DCS system: 1. All-round integrated control system, integrating DCS & PLC & Field Bus; 2. Using RISC SuperScalar high-speed CPU, with super performance; Three high reliability, strict industrial application practice, more than 1000 sets of application performance in China; 4. It has good openness, flexibility and scalability; Fifth, the project is easy, the interface is…

D137-001-011 MOOG

system’s Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance. System engineering is very convenient. The configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram (LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration…

D137-001-007 MOOG

the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured -Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly. S800 and S900 are distributed i/0 for process control stations. They communicate…

D137-001-005 MOOG

interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other Redundant basic unit pm802f) and can be plugged in and out and replaced online.…

D136-001-008 MOOG

battery (matchdog, optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the…