NI-9159

connection of 4 high-speed fieldbuses (max. 12 MBd) Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field including equipment management information Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage systems Module identification with production operating…

NI-9157

logic operation Monitoring function Collection function. c arithmetic operations c TCP/IP protocol communication interface Modbus protocol communication interface 1EC870-5 protocol communication interface (Telecontrol) 4.2 Field Controller PS Industrial” field controller PS is a special process control station, which is embedded with field bus communication interface for users to use Fieldbus technology offers very flexible options.…

NI-9112

Profibus is the most widely used open fieldbus international standard in the world, divided into FMS, DP and PA Level 3, DP communication rate can be as high as 12Mb. Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus instruments. Communication between the process station, operator station and engineering…

NI-9036

and debugging of process level, operation level and even fieldbus instruments, and uses the same a global database. The scale of the system is highly scalable, and a single-system supports 1 to a maximum of 100 control stations and 100 operating stations. each control The station can support several thousand I/0 points at most, and…

NI-9031

the communication transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application. The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform. tower. The operating station 0S, the engineering station ES and…

NI-9025

selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation Away. And the redundant operation is realized by two redundant field controllers. Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station The i/0 protection unit of the PS is used…

NI-9014

fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the…

NI-9012

operation speed of 150 MIPS 4 MB FLASH-EPROM EEPROM,serial, 16 Kbit o Ram 8 MB (with error check and correction function, abb patent) 16 K internal cache (CPU cache RAM) Ram backup battery (matchdog, optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms…

NI-8464

Redundant communication link (diginetr) to ensure information synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation. The data communication between the field process controller PS. operating station 0s and the engineer…

NI-8422

25KBd Foundation Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS. Industrial “field control explosion (AC800F) consists of the following components: Basic unit pm802f Power supply sa801f/sd802f Ethernet network card ei801f/ei802f/ei803f o Fieldbus interface card fi810f/fi820f/fi830f Various accessories The…