DF8203490-A0

Panel Wiring DIN rail (U-shaped) installation well can be directly wall mounted, simple and convenient o Allowable operating ambient temperature…60 C, with automatic temperature monitoring o EMC (Electromagnetic Compatibility) according to EN50082 mouth Certifications: CE, NAMUR, CSA, CSA-NRT Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A…

JANCD-JIF03

communication interface for users to use Fieldbus technology offers very flexible options. Each PS allows to insert 4 fieldbus interface cards (the card type can be different), Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and…

JANCD-GSYO

engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables and mixed media) and network topology can be selected for the system bus. Simple layout, due to the use of TCP/IP protocol, the system can also use the public telephone network…

DF9200471-E0

wall. System complies with all current EMC standards and is CE marked Chi. Industrial” DCS system design purpose: the most economical engineering investment, the most powerful control function. Five features of Industria1″ DCS system: 1. All-round integrated control system, integrating DCS & PLC & Field Bus; 2. Using RISC SuperScalar high-speed CPU, with super performance;…

JASP-WRCA01

redundant PS. can be switched redundantly. S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its…

JANCU-MSV01B

settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other Redundant basic unit pm802f) and can be plugged in and out…

JANCD-MIF06

MIPS 4 MB FLASH-EPROM EEPROM,serial, 16 Kbit o Ram 8 MB (with error check and correction function, abb patent) 16 K internal cache (CPU cache RAM) Ram backup battery (matchdog, optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16…

JANCD-IF21

to form a special Redundant communication link (diginetr) to ensure information synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation. The data communication between the field process controller PS. operating station…

JANCD-G5CO1B

o Open CAN -Bus,up to 1 MBd o Foundation Fieldbus H1 up to 31. 25KBd Foundation Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS. Industrial “field control explosion (AC800F) consists of the following components: Basic unit pm802f Power…

JANCD-GSPI0

and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the same tool…