132147-1JANCD

technical upgrades and maintenance. System engineering is very convenient. The configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram (LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions Algorithm library for energy blocks and…

JZRCR-XSU02

distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its super sturdiness and data security. The system of course also…

JANCD-G1O02

Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd One PS can plug in 4 fieldbus interfaces, connect 496 fieldbus devices, and one city (subsystem) of industrial “system can Connect 4960 fieldbus devices (10000 i/0). Fi820f: two serial interfaces are provided…

JZNC-IOP02C

instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard) Interface. Basic characteristics: 1ee802.3 Ethernet standard o Ei801f provides 10base2 thin cable communication interface Ei802f provides 10BASE5 thick cable connection (through AUI interface) Ei803f provides 10Base-T twisted pair communication interface 32-bit data bus, 100…

JANCD-HA03REV.D

information will be automatically reloaded. The configuration results and real-time process data are stored in RAM, and ram is installed on the Ethernet network card or battery card The backup battery can maintain the configuration content and data in case of power failure. Basic unit pmbo2f characteristics: mouth Installation slots of 4 fieldbus interface cards…

JANCD-MB20

redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special Redundant communication link (diginetr) to ensure information synchronization between master and slave…

JANCD-FC850

following types of fieldbus standards: Profibus DP,up to 12 MBd Modbus RTU,1200 to 38. 4KBd Industrial” CAN I/0 Bus o Open CAN -Bus,up to 1 MBd o Foundation Fieldbus H1 up to 31. 25KBd Foundation Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in…

JANCD-CG06

play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the same tool CBF (control build f)…

JANCD-CU20

control All schemes can be realized by the combination of these function blocks. The function blocks provided by the system mainly fall into the following categories: o Analog quantity processing o Digital quantity processing Loop adjustment Logical sequence control c Logical operation Monitoring function Acquisition function c Arithmetic operation c Tcp/ip protocol communication interface Modbus…

SL-2B

widely used open fieldbus international standard in the world, which is divided into FMS, DP and pa Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through…