jancd-fc120

to the basic ones specified in the IEC 61131 3 standard In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control The scheme can be realized by the combination of these function blocks. The function blocks provided by the system mainly include the…

JANCD-EI0O1

communication Industrial” system uses international standard industrial bus. Field controller supports Profibus, FF, ModBus, Can, etc. International standard fieldbus, Profibus is the most widely used open fieldbus international standard in the world, divided into FMS, DP and PA Level 3, DP communication rate can be as high as 12Mb. Profibus is used to connect intelligent…

JANCD-G1002

supports 1 to a maximum of 100 control stations and 100 operating stations. each control The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is encapsulated in an all-metal shell, which can withstand the most Harsh industrial…

JANCD-FC400

the communication transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application. The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform. tower. The operating station 0S, the engineering station ES and…

JANCD-EI005

controllers. Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured -Block fi810f…

JANCD-MBB04

operating load <4% Optional ram backup battery Fieldbus interface replacement card fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0)…

jancd-fc430

interface cards c Installation slot of 2 Ethernet network cards Support redundant operation of Fieldbus interface card Support hot plug of Fieldbus interface card Technical indicators of basic unit pib02f: CPU :Intel 80960HT25/75 32-bit RISC superscalar processor with operation speed of 150 MIPS 4 MB FLASH-EPROM EEPROM,serial, 16 Kbit o Ram 8 MB (with error…

JANCD-B

network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special Redundant communication link (diginetr) to ensure information synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and…

JZRCR-NTU01B

diagnosis Compact and rugged design Front panel wiring DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient o Allowable operating ambient temperature 60 C, automatic temperature monitoring o EMC (electromagnetic compatibility) conforms to en50082 standard mouth Certification: CE, Namur, CSA, csa-nrtl, FM class 1 div2, ghost, Lloyd…

JZNC-TU11

communication interface (telecontrol) 4.2 field controller PS Industrial ial “field controller PS is a special process control station, which is embedded with a fieldbus communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is…