G122-829-001

connection of 4 high-speed fieldbuses (max. 12 MBd) Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field including equipment management information Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage systems Module identification with production operating…

G040-124-002

powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control The scheme can be realized by the combination of these function blocks. The function blocks provided by the system mainly include the following categories: o Analog processing o digital processing loop regulation Logical sequence control c logic operation Monitoring…

G040-123-001

China; 4. It has good openness, flexibility and scalability; Fifth, the project is easy, the interface is friendly, and the maintenance is simple; 2. Industria1″ system communication Industrial” system uses international standard industrial bus. Field controller supports Profibus, FF, ModBus, Can, etc. International standard fieldbus, Profibus is the most widely used open fieldbus international standard…

G122-202A001

more than 200 graphic symbols and an extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete the configuration and debugging of process level, operation level and even fieldbus instruments, and uses the same a global database. The scale of the system is highly…

G122-202

selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation Away. And the redundant operation is realized by two redundant field controllers. Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station The i/0 protection unit of the PS is used…

G122-829-003

bit data bus, 100 mb/s DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4% Optional ram backup battery Fieldbus interface replacement card fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration…

G122-824-002

power failure. Basic unit pmbo2f characteristics: mouth Installation slots of 4 fieldbus interface cards c Installation slot of 2 Ethernet network cards Support redundant operation of Fieldbus interface card Support hot plug of Fieldbus interface card Technical indicators of basic unit pib02f: CPU :Intel 80960HT25/75 32-bit RISC superscalar processor with operation speed of 150 MIPS…

072F586A5-HP5

Redundant communication link (diginetr) to ensure information synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation. The data communication between the field process controller PS. operating station 0s and the engineer…

G761-3006B

FM class 1 div2, ghost, Lloyd Installation area: Class 1 div 2 The PS supports the following types of fieldbus standards: Profibus DP,up to 12 MBd Modbus RTU,1200 to 38. 4KBd Industrial” CAN I/0 Bus o Open CAN -Bus,up to 1 MBd o Foundation Fieldbus H1 up to 31. 25KBd Foundation Fieldbus H2 (fast Ethernet)…

743F002B

different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is easy to replace and plug and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international…