5X00499G01

standards Annals. Industrial “DCS system design purpose: the most economical engineering investment and the most powerful control function. Industria1 “five features of DCS system: 1、 The comprehensive control system integrates DCS & PLC & field bus; 2、 RISC superscalar high-speed CPU with super performance; 3. High reliability, strict industrial application practice, and application performance of…

1X00691H01

configuration modes. The system contains about 220 functions The algorithm library of energy block, the basic library with more than 200 graphic symbols and the extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete the configuration and commissioning of process level, operation level…

5X00500G01

ginets network (Industrial Ethernet /iee802.3 standard), The user can select the communication transmission medium (ordinary cable or optical fiber) and network topology structure according to the actual situation of the application. Popular PC and MS_ Wi ndows2000 has been widely used in various fields all over the world and has become the de facto standard…

1C31227G01

Yes. The process control level realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between the controller and various intelligent devices such as i/0 or field instruments) adopts the international standard field…

5X00070G01

complex analog loop regulation function of DCS Friendly human-machine interface (HMI) and convenient engineering software, as well as high-speed logic and sequence control equivalent to high-grade PLC indicators Braking performance. The system can connect not only conventional i/0, but also PROFIBUS, FF, can, MODBUS and other field bus devices. System tool It has high flexibility…

1C31227G01

printing, trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems. can. The process control stage realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control. Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between…

1C31224G01

can be connected to both conventional I/0 and various field bus devices such as Profibus, FF, CAN, and Modbus. system tool It has a high degree of flexibility and excellent scalability, whether it is the control of small production units, or the control of ultra-large-scale whole plants – integrated control, even The Industrial” system can…

5X00121G01

1990, it obtained the DQS certificate based on ISO9001 certification, EQnet quality based on ISO 9000/EN 29000 was subsequently achieved Certification. However, the Freelance 800F is more than technical excellence, I We have also spent a lot of effort in proper planning, installation and revision too This makes engineering design and maintenance faster, more economical…

5X00119G01

system applications, it is suitable for implementing user Communicate with non-standard OPC, ie DMS-API software package. Project database All configured signals, variables and process points are in Freelance 800F system’s public database for management. ● List of all variables (input, output, internal variables) ● Process point list (function block) ●Graphics ●Program Because the database is…

1C31116G04

process control stations connected to I/O units. you can choose this Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field device…