PM864AK02

PM864AK02 regulation function of DCS Friendly human-machine interface (HMI) and convenient engineering software, as well as high-speed logic and sequence control equivalent to high-grade PLC indicators Braking performance. The system can connect not only conventional i/0, but also PROFIBUS, FF, can, MODBUS and other field bus devices. System tool It has high flexibility and excellent…

PM866K01

PM866K01 and supports a variety of international field bus standards. It has both the complex analog loop regulation capability of DCS Power-friendly human-machine interface (HMI) and convenient engineering software, and at the same time have high-speed logic and sequence control equivalent to high-end PLC indicators. control performance. The system can be connected to both conventional…

PM866K02

PM866K02 device via fieldbus ready.   system communication Communication between operator level and process control level using TCP/IP Protocol system bus (based on Ethernet), you can choose different transmission medium such as AUI, twisted pair, fiber optic or coaxial cable. Freelance OPC server for connecting to higher-level operators station (800xA) or other OPC client. Freelance…

SB822

SB822 integrity and consistency check of the user program. ●The programming language strictly complies with the international standard of IEC61131-3, and has There are high-performance graphics editing functions: – Function Block Diagram (FBD) -Ladder Diagram (LD) – Instruction List (IL) – Sequence Control Chart (SFC) . Structured Text (ST) ●Extensive function block library, user-defined function…

TK212A

TK212A Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller.…

TC562

TC562 Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field including equipment management information Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage systems Module identification with production operating parameters c  complete self-diagnosis Compact and robust…

PFEIFFER CMR361

PFEIFFER CMR361The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform to ensure the system’s Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance. System engineering is very convenient. The configuration language is based on the IE061131 3…

SIEMENS 3RK3131-2AC10

SIEMENS 3RK3131-2AC10equivalent to high-end PLC indicators. control performance. The system can be connected to both conventional I/0 and various field bus devices such as Profibus, FF, CAN, and Modbus. system tool It has a high degree of flexibility and excellent scalability, whether it is the control of small production units, or the control of ultra-large-scale…

HIMA 4135A

HIMA 4135A applications, it is suitable for implementing user Communicate with non-standard OPC, ie DMS-API software package. Project database All configured signals, variables and process points are in Freelance 800F system’s public database for management. ● List of all variables (input, output, internal variables) ● Process point list (function block) ●Graphics ●Program Because the database…

BENTLY 146031-01

BENTLY 146031-01 these devices. ●Profibus field controller can be integrated through FDT/DTM technology line equipment   system structure The Freelance 800F process control system is divided into operator levels and process control level. The operator level contains controls for operation and display. Archiving and logging, trending and alarming functions. Controller executes open loop and closed…