PTAI216

PTAI216 process control station and the operator station According to communication.     For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment in establishing data communication and interactive access. And ensure the consistency of data throughout the system.…

PATI216

PATI216 Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller.…

OT115/R

OT115/R replace and plug and play (Plug & Play), and can be plugged and unplugged. The field controller PS has the following characteristics: o  Flexible: supports all international standard open fieldbuses and can be mixed Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd) Simple engineering: configuration, commissioning and diagnostics using only the same tool…

NT255

NT255 used open fieldbus international standard in the world, divided into FMS, DP and PA Level 3, DP communication rate can be as high as 12Mb. Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus instruments. Communication between the process station, operator station and engineering station takes place via…

MX213

MX213 engineering is very convenient. The configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram (LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions Algorithm library for energy blocks and a basic library with…

MPC270

MPC270field controller supports various field buses such as Profibus. Profibus is the most widely used open field bus in the world. Line international standard, divided into FMS, DP and PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its super sturdiness and data…

MPC240

MPC240Automation Headquarters. It integrates the advantages of traditional DCS and PLC in one body and supports a variety of international field bus standards. It has both the complex analog loop regulation capability of DCS Power-friendly human-machine interface (HMI) and convenient engineering software, and at the same time have high-speed logic and sequence control equivalent to…

MC205

MC205 transmission medium such as AUI, twisted pair, fiber optic or coaxial cable. Freelance OPC server for connecting to higher-level operators station (800xA) or other OPC client. Freelance Control System Real-time process values ??and alarms in the system can be accessed via OPC. We also provide a C language programming interface to embed external In…

LM201

LM201 complies with the international standard of IEC61131-3, and has There are high-performance graphics editing functions: – Function Block Diagram (FBD) -Ladder Diagram (LD) – Instruction List (IL) – Sequence Control Chart (SFC) . Structured Text (ST) ●Extensive function block library, user-defined function blocks can also be added Added to it, the macro library and…

ISI222

ISI222 important. Generally speaking, a self The engineering application software cost of the automation project accounts for about the entire project. About 50%, it is not difficult to see that the migration of cost structure creates a lot of innovation for users. Create an opportunity to optimize project investment, therefore, it is necessary to start…