EPRO PR9268/300-000

EPRO PR9268/300-000 encapsulated in an all-metal shell, which can withstand the most Harsh industrial environment. The device can be installed either in a cabinet or on a wall. System complies with all current EMC standards and is CE marked Chi.  Industrial” DCS system design purpose: the most economical engineering investment, the most powerful control function.…

EPRO PR6424/000-000+CON021

EPRO PR6424/000-000+CON021as I/0 or field instruments) adopts the international standard field controller. Wire. The field controller supports various field buses such as Profibus. Profibus is the most widely used open field bus in the world. Line international standard, divided into FMS, DP and PA three levels, DP communication rate can be as high as 12Mb.…

EPRO PR6423/002-000+CON021

EPRO PR6423/002-000+CON021 uickly find the desired variable or process point within the scope noodle. ABB is the world’s largest in measurement and process automation One of the equipment and system suppliers. An important factor in maintaining this market position is the quality of our products quantity, and quality from manufacture all the way to service.…

EPRO PR6423/000-040

EPRO PR6423/000-040 configures and adjusts the system Mode. Usually, we can use portable devices such as notebooks to The system is now configured in the office and on site. Operator-level PC Can also be used as an engineer station. Engineer standing during system uptime Intervals can be closed without a permanent connection to the system.…

EPRO MMS6822

EPRO MMS6822 entire control system, including automation functions function, operator interface display and logging, and configuration of the fieldbus. equipment (PROFIBUS, FOUNDATION Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station and the operator station According to communication.     For field devices, process control stations…

EPRO MMS6220

EPRO MMS6220 interface cards (the card type can be different), Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and play (Plug & Play), and can be plugged and unplugged. The field controller PS has the following…

EPRO CON021+PR6424/010-100

EPRO CON021+PR6424/010-100 distributed I/0 stations and field bus instruments. Communication between the process station, operator station and engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables and mixed media) and network topology can be selected for the system bus. Simple…

EPRO PR6424/010-030

EPRO PR6424/010-030 Ethernet/IEEE802.3 standard), Users can choose the communication transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application. The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform. tower. The operating…

EPRO PR6423/003-030

EPRO PR6423/003-030 redundantly (separated between each other Redundant basic unit pm802f) and can be plugged in and out and replaced online. Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd One PS can plug in 4 fieldbus interfaces, connect 496 fieldbus…

EPRO PR6453/110-101

EPRO PR6453/110-101 inserted The – Ethernet network card on the PS basic unit provides the interface between PS and diginets. ES. Hardware configuration and PS The user program is downloaded to the PS CPU through diginets and the first network card. After the field bus interface card is newly installed or replaced, the required group…