xVME-564

xVME-564 production operating parameters c complete self-diagnosis Compact and robust design Front Panel Wiring DIN rail (U-shaped) installation well can be directly wall mounted, simple and convenient o Allowable operating ambient temperature…60 C, with automatic temperature monitoring o EMC (Electromagnetic Compatibility) according to EN50082 mouth Certifications: CE, NAMUR, CSA, CSA-NRT Glossary Process station: This term…

XVME-560

XVME-560modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control The scheme can be realized by the combination of these function blocks. The function blocks provided…

xVME-542

xVME-542 most, and the scale of the whole system can be expanded. The hardware of the system control station is encapsulated in an all-metal shell, which can withstand the most Harsh industrial environment. The device can be installed either in a cabinet or on a wall. System complies with all current EMC standards and is…

XVME-540

XVME-540 Fieldbus Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through IART protocol…

XVME-531

XVME-531 interface 32-bit data bus, 100 mb/s DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4% Optional ram backup battery Fieldbus interface replacement card fi830f/fi820f/fi810  f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS,…

XVME-505

XVME-505 synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation.   The data communication between the field process controller PS. operating station 0s and the engineer station es is completed by…

XVME-500

XVME-500 including equipment management information Global database of Fieldbus equipment, control level and HMI (human-machine interface) Module identification with production operating parameters c Complete self diagnosis Compact and rugged design Front panel wiring DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient   o Allowable operating ambient…

xVME- -290

xVME- -290 PROFIBUS is the most widely used open fieldbus international standard in the world, which is divided into FMS, DP and pa Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station…

xVME- -260

xVME- -260 station es and data gateway GS of the industrial “system have adopted this platform, thus ensuring the It is universal, open and easy to use, and brings great convenience for future technology upgrading and maintenance. System engineering configuration is very convenient. The configuration language is based on ie0611313 industrial standard and provides function…

XVME-244

XVME-244 led by ABB in technology Information technology) a new trend. The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is realized Can (operate and display, print, trend display and alarm), and also complete system hardware…