SCHNEIDER 140DA084010

system supports 1 to a maximum of 100 control stations and 100 operating stations. each control The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is encapsulated in an all-metal shell, which can withstand the most  Harsh…

SCHNEIDER 140DA084000

computer platform. tower. The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform to ensure the system’s Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance. System engineering is very convenient. The configuration language is based on the…

SCHNEIDER 140DSI35300

redundant PS. can be switched redundantly. S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its…

SCHNEIDER 140DII33000

(separated between each other Redundant basic unit pm802f) and can be plugged in and out and replaced online. Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd One PS can plug in 4 fieldbus interfaces, connect 496 fieldbus devices, and one…

SCHNEIDER 140DDI84100

redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network diginet…

SCHNEIDER 140DI35310

outputs also support redundant operation.   The data communication between the field process controller PS. operating station 0s and the engineer station es is completed by the system network (diginets), which is inserted The – Ethernet network card on the PS basic unit provides the interface between PS and diginets. ES. Hardware configuration and PS…

SCHNEIDER 140DI36400

fi810f/fi820f/fi830f Various accessories The main components of the field controller PS are described below. Basic unit pm802f The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the The signals of the field bus sensors are processed according to the control application program configured by…

SCHNEIDER 140DD115310

identification with production operating parameters c Complete self diagnosis Compact and rugged design Front panel wiring DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient   o Allowable operating ambient temperature 60 C, automatic temperature monitoring o EMC (electromagnetic compatibility) conforms to en50082 standard mouth Certification: CE,…

SCHNEIDER 140DAI75300

function c Arithmetic operation c Tcp/ip protocol communication interface Modbus protocol communication interface 1ec870-5 protocol communication interface (telecontrol) 4.2 field controller PS Industrial ial “field controller PS is a special process control station, which is embedded with a fieldbus communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is…

SCHNEIDER 140DAI74000

twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network topology can be selected for the system bus Due to the adoption of tcp/ip protocol, the system can also realize ultra long distance communication with the help of public telephone network (dial-up mode) or satellite. PLC and other subsystems communicate…