51304501-100

and used according to the type and number of system process signals. AC800F controller connects remote I/O or field device via fieldbus ready. system communication Communication between operator level and process control level using TCP/IP Protocol system bus (based on Ethernet), you can choose different transmission medium such as AUI, twisted pair, fiber optic or…

51304493-200

that is to say, two operations can be performed using one PC station and operate with a mouse and a keyboard. Operator level can install one engineering station and several operators stand. ControlBuilderF engineering station configures and adjusts the system Mode. Usually, we can use portable devices such as notebooks to The system is now…

51304493-100

symbols can be customized for the user. Blocks can create graphics and operator panels. ●Any standard can be integrated by means of GSD file import PROFIBUS-DP and PA devices, and through user-defined pairing dialog box to design the configuration window for these devices. ●Profibus field controller can be integrated through FDT/DTM technology line equipment system…

51304199-100

communication.   For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment in establishing data communication and interactive access. And ensure the consistency of data throughout the system. ●Provide system-wide unified inspection of user applications, overriding from process control…

51304156-100

engineering applications The cost of software becomes increasingly important. Generally speaking, a self The engineering application software cost of the automation project accounts for about the entire project. About 50%, it is not difficult to see that the migration of cost structure creates a lot of innovation for users. Create an opportunity to optimize project…

51303997-300

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F 😡  This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

51303994-300

are described below. Basic unit pm802f The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the The signals of the field bus sensors are processed according to the control application program configured by the user, and then the calculation results are passed The fieldbus…

51303979-500

rugged design Front panel wiring DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient   o Allowable operating ambient temperature 60 C, automatic temperature monitoring o EMC (electromagnetic compatibility) conforms to en50082 standard mouth Certification: CE, Namur, CSA, csa-nrtl, FM class 1 div2, ghost, Lloyd Installation area:…

51303979-400

which is embedded with a fieldbus communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is…

10001/R

supports iec870-5 over control coordination Discussion.   The flash EPROM inside PS provides more than 220 function modules (control algorithm subroutines), in addition to the base specified in IEC 61131 3 standard In addition to this content, many powerful and strictly tested function blocks from practical engineering applications are also expanded. Any complex control All…