SUPPLY 51195066-200

communication interface for users to use Fieldbus technology offers very flexible options. Each PS allows to insert 4 fieldbus interface cards (the card type can be different), Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and…

MCPI 51109919-100

achieve ultra-long-distance communication. Subsystems such as PLC communicate with the Industrial” system through the ModBus protocol interface. The system also supports IEC870-5 over-control protocol. discussion.  The Flash EPROM inside the PS provides more than 220 functional modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard In addition…

LCH I0 51107403-100

flexibility and scalability; Fifth, the project is easy, the interface is friendly, and the maintenance is simple; 2. Industria1″ system communication Industrial” system uses international standard industrial bus. Field controller supports Profibus, FF, ModBus, Can, etc. International standard fieldbus, Profibus is the most widely used open fieldbus international standard in the world, divided into FMS,…

LLCN 5141291-100

than 200 graphic symbols and an extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete the configuration and debugging of process level, operation level and even fieldbus instruments, and uses the same a global database. The scale of the system is highly scalable,…

51303979- 400

biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through IART protocol or field bus (31. 25Kb ProfibusPA and FF bus). The system communication between the operation management level and the process control level is realized by Di giNetS network…

CARD 51303944-100

maximum transmission rate is 38.4kbd and can be configured. Its Standards Association Modbus Different physical interfaces can be selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation Away. And the redundant operation is realized by two redundant field controllers. Fi8i0f card is a triple can bus protocol interface card (rate 1mbd)…

CARD 51303947-100

100 mb/s DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4% Optional ram backup battery Fieldbus interface replacement card fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings…

SUPPLY 51196653-100

network cards Support redundant operation of Fieldbus interface card Support hot plug of Fieldbus interface card Technical indicators of basic unit pib02f: CPU :Intel 80960HT25/75 32-bit RISC superscalar processor with operation speed of 150 MIPS 4 MB FLASH-EPROM EEPROM,serial, 16 Kbit o Ram 8 MB (with error check and correction function, abb patent) 16 K…

WREN II 51108676-100

synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation. The data communication between the field process controller PS. operating station 0s and the engineer station es is completed by the system…

DRIVE 51195155-100

Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS. Industrial “field control explosion (AC800F) consists of the following components: Basic unit pm802f Power supply sa801f/sd802f o Ethernet network card ei801f/ei802f/ei803f o Fieldbus interface card fi810f/fi820f/fi830f Various accessories The main…