klcn I0. CA 51304542-100

on Ethernet), you can choose different transmission medium such as AUI, twisted pair, fiber optic or coaxial cable. Freelance OPC server for connecting to higher-level operators station (800xA) or other OPC client. Freelance Control System Real-time process values ??and alarms in the system can be accessed via OPC. We also provide a C language programming…

KLCH I0_ CB 51304544-100

that is to say, two operations can be performed using one PC station and operate with a mouse and a keyboard. Operator level can install one engineering station and several operators stand. ControlBuilderF engineering station configures and adjusts the system Mode. Usually, we can use portable devices such as notebooks to The system is now…

HodT I0 51304913-100

standard of IEC61131-3, and has There are high-performance graphics editing functions: – Function Block Diagram (FBD) -Ladder Diagram (LD) – Instruction List (IL) – Sequence Control Chart (SFC)   . Structured Text (ST) ●Extensive function block library, user-defined function blocks can also be added Added to it, the macro library and graphic symbols can be…

WS12 I0 51304924-100

engineering cost? ●By using a complete engineering tool (Control Builder F) to configure the entire control system, including automation functions function, operator interface display and logging, and configuration of the fieldbus. equipment (PROFIBUS, FOUNDATION Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station and the operator…

CLcN I0 51305072-400

contains 2 rack-mounted CPUs. This term is used to describe a single, non-redundant process station. In the investment of modern automation system, due to the hardware equipment department It only takes up less cost in the whole system, then write engineering applications The cost of software becomes increasingly important. Generally speaking, a self The engineering…

LCN 51400667-100

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

MCPU 51400664-100

the configuration content and data in case of power failure. Basic unit pmbo2f characteristics: mouth Installation slots of 4 fieldbus interface cards c Installation slot of 2 Ethernet network cards Support redundant operation of Fieldbus interface card Support hot plug of Fieldbus interface card Technical indicators of basic unit pib02f: CPU :Intel 80960HT25/75 32-bit RISC…

WDC 51400668-100

controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special Redundant communication link (diginetr) to ensure information synchronization between master…

FDC 51 400669-100

standards: Profibus DP,up to 12 MBd Modbus RTU,1200 to 38. 4KBd Industrial” CAN I/0 Bus o Open CAN -Bus,up to 1 MBd o Foundation Fieldbus H1 up to 31. 25KBd Foundation Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller…

SUPPLI 51400712-200

and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the same tool…