5X00001H15

system: 1. All-round integrated control system, integrating DCS & PLC & Field Bus; 2. Using RISC SuperScalar high-speed CPU, with super performance; Three high reliability, strict industrial application practice, more than 1000 sets of application performance in China; 4. It has good openness, flexibility and scalability; Fifth, the project is easy, the interface is friendly,…

5A26499G01

topology according to the actual situation of the application. The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform. tower. The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform…

5A26481G01

fieldbuses and can be mixed Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd) Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field including equipment management information Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage…

5A26479G07

protocol. discussion. The Flash EPROM inside the PS provides more than 220 functional modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control The scheme can…

5A26479G06

topology according to the actual situation of the application. The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform. tower. The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform…

5A26479G03

redundant PS. can be switched redundantly. S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its…

5A26479G02

fieldbus communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is easy to replace and plug…

5A26479G01

the system bus Due to the adoption of tcp/ip protocol, the system can also realize ultra long distance communication with the help of public telephone network (dial-up mode) or satellite. PLC and other subsystems communicate with industrial “system through Modbus protocol interface. The system also supports iec870-5 over control coordination Discussion.   The flash EPROM…

5A26458G02

supports PROFIBUS, FF, MODBUS, can and other countries International standard fieldbus, PROFIBUS is the most widely used open fieldbus international standard in the world, which is divided into FMS, DP and pa Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other…

5A26453G01

expanded. The hardware of the system control station is all metal enclosure, which can withstand the most Harsh industrial environment. The equipment can be installed in the cabinet or on the wall. The system complies with all current EMC standards and has CE standards Annals. Industrial “DCS system design purpose: the most economical engineering investment…