1C31227G01

printing, trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems. can. The process control stage realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control. Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between…

1C31224G01

can be connected to both conventional I/0 and various field bus devices such as Profibus, FF, CAN, and Modbus. system tool It has a high degree of flexibility and excellent scalability, whether it is the control of small production units, or the control of ultra-large-scale whole plants – integrated control, even The Industrial” system can…

5X00121G01

1990, it obtained the DQS certificate based on ISO9001 certification, EQnet quality based on ISO 9000/EN 29000 was subsequently achieved Certification. However, the Freelance 800F is more than technical excellence, I We have also spent a lot of effort in proper planning, installation and revision too This makes engineering design and maintenance faster, more economical…

5X00119G01

system applications, it is suitable for implementing user Communicate with non-standard OPC, ie DMS-API software package. Project database All configured signals, variables and process points are in Freelance 800F system’s public database for management. ● List of all variables (input, output, internal variables) ● Process point list (function block) ●Graphics ●Program Because the database is…

1C31116G04

process control stations connected to I/O units. you can choose this Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field device…

5X00070G04

keyboard. Operator level can install one engineering station and several operators stand. ControlBuilderF engineering station configures and adjusts the system Mode. Usually, we can use portable devices such as notebooks to The system is now configured in the office and on site. Operator-level PC Can also be used as an engineer station. Engineer standing during…

1C31132G01

by means of GSD file import PROFIBUS-DP and PA devices, and through user-defined pairing dialog box to design the configuration window for these devices. ●Profibus field controller can be integrated through FDT/DTM technology line equipment   system structure The Freelance 800F process control system is divided into operator levels and process control level. The operator…

1C31129G03

and interactive access. And ensure the consistency of data throughout the system. ●Provide system-wide unified inspection of user applications, overriding from process control stations, operator stations to intelligent field devices, including Including the integrity and consistency check of the user program. ●The programming language strictly complies with the international standard of IEC61131-3, and has There…

1C31238H01

migration of cost structure creates a lot of innovation for users. Create an opportunity to optimize project investment, therefore, it is necessary to start from engineering programming Think about lowering costs in the first place! This is what we developed the Freelance 800F system for: Keeping hardware prices consistent with those of programmable logic controllers…

1C31234G01

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…