5X00327G01

replacement card fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed…

5X00301G01

optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network…

5X0026144G01

configuration and PS The user program is downloaded to the PS CPU through diginets and the first network card. After the field bus interface card is newly installed or replaced, the required group The status information will be automatically reloaded. The configuration results and real-time process data are stored in RAM, and ram is installed…

5X00226G03

controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special Redundant communication link (diginetr) to ensure information synchronization between master…

5X00481G01

H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS. Industrial “field control explosion (AC800F) consists of the following components: Basic unit pm802f Power supply sa801f/sd802f o Ethernet network card ei801f/ei802f/ei803f o Fieldbus interface card fi810f/fi820f/fi830f Various accessories The main components…

3A99190G01

and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the same tool…

5X00105G14

modules (control algorithm subroutines), in addition to the base specified in IEC 61131 3 standard In addition to this content, many powerful and strictly tested function blocks from practical engineering applications are also expanded. Any complex control All schemes can be realized by the combination of these function blocks. The function blocks provided by the…

5X00226G01

which is divided into FMS, DP and pa Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission…

5X00241G02

expanded. The hardware of the system control station is all metal enclosure, which can withstand the most Harsh industrial environment. The equipment can be installed in the cabinet or on the wall. The system complies with all current EMC standards and has CE standards Annals. Industrial “DCS system design purpose: the most economical engineering investment…

5X00225G01

thus ensuring the It is universal, open and easy to use, and brings great convenience for future technology upgrading and maintenance. System engineering configuration is very convenient. The configuration language is based on ie0611313 industrial standard and provides function block diagram (FBD) and ladder diagram (LD), instruction list (IL), sequential function diagram (SFC), structured text…