IC694MDL645

IART protocol or field bus (31. 25Kb ProfibusPA and FF bus). The system communication between the operation management level and the process control level is realized by Di giNetS network (Industrial Ethernet/IEEE802.3 standard), Users can choose the communication transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the…

IC693CPU367

RS422, RS485, RS232. All interfaces are electrical isolation Away. And the redundant operation is realized by two redundant field controllers. Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station The i/0 protection unit of the PS is used to receive process signals from…

IC693CPU366

types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the industrial “unified tool control bui lder without additional…

IC697CPX935

function, abb patent) 16 K internal cache (CPU cache RAM) Ram backup battery (matchdog, optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet…

1C697CPX928

PS basic unit provides the interface between PS and diginets. ES. Hardware configuration and PS The user program is downloaded to the PS CPU through diginets and the first network card. After the field bus interface card is newly installed or replaced, the required group The status information will be automatically reloaded. The configuration results…

1C697CPX782

bus sensors are processed according to the control application program configured by the user, and then the calculation results are passed The fieldbus interface card returns the corresponding fieldbus actuator. Two field controllers can realize controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second…

IC697CPX772

(max. 12 MBD) Simple project: only use the same tool CBF (control build f) software for configuration, debugging and diagnosis mouth Access to all information from the site, including equipment management information Global database of Fieldbus equipment, control level and HMI (human-machine interface) Module identification with production operating parameters c Complete self diagnosis Compact and…

IC697CPU789

Analog quantity processing o Digital quantity processing Loop adjustment Logical sequence control c Logical operation Monitoring function Acquisition function c Arithmetic operation c Tcp/ip protocol communication interface Modbus protocol communication interface 1ec870-5 protocol communication interface (telecontrol) 4.2 field controller PS Industrial ial “field controller PS is a special process control station, which is embedded with…

IC697CPU788

Ethernet). user Different transmission media (RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network topology can be selected for the system bus Due to the adoption of tcp/ip protocol, the system can also realize ultra long distance communication with the help of public telephone network (dial-up mode) or…

IC697CPU780

standards Annals. Industrial “DCS system design purpose: the most economical engineering investment and the most powerful control function. Industria1 “five features of DCS system: 1、 The comprehensive control system integrates DCS & PLC & field bus; 2、 RISC superscalar high-speed CPU with super performance; 3. High reliability, strict industrial application practice, and application performance of…