ACS510-01-031A-4

ACS510-01-031A-4 (31.25kb profibuspa and FF Bus). The system communication between the operation management level and the process control level is realized by the di ginets network (Industrial Ethernet /iee802.3 standard), The user can select the communication transmission medium (ordinary cable or optical fiber) and network topology structure according to the actual situation of the application.…

ACS510-01-038A-4

ACS510-01-038A-4 the process control station (between the controller and various intelligent devices such as I/0 or field instruments) adopts the international standard field controller. Wire. The field controller supports various field buses such as Profibus. Profibus is the most widely used open field bus in the world. Line international standard, divided into FMS, DP Industrial…

ACS510-01-046A-4

ACS510-01-046A-4 from manufacture all the way to service. ABB automation early In 1990, it obtained the DQS certificate based on ISO9001 certification, EQnet quality based on ISO 9000/EN 29000 was subsequently achieved Certification. However, the Freelance 800F is more than technical excellence, I We have also spent a lot of effort in proper planning, installation…

ACS510-01-060A-4

ACS510-01-060A-4 process control stations connected to I/O units. you can choose this Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field…

ACS510-01-072A-4

ACS510-01-072A-4 the consistency of data throughout the system. ●Provide system-wide unified inspection of user applications, overriding from process control stations, operator stations to intelligent field devices, including Including the integrity and consistency check of the user program. ●The programming language strictly complies with the international standard of IEC61131-3, and has There are high-performance graphics editing…

ACS510-01-088A-4

ACS510-01-088A-4 Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller.…

ACS510-01-125A-4

ACS510-01-125A-4 library, user-defined function blocks can also be added Added to it, the macro library and graphic symbols can be customized for the user. Blocks can create graphics and operator panels. ●Any standard can be integrated by means of GSD file import PROFIBUS-DP and PA devices, and through user-defined pairing dialog box to design the…

ACS510-01-157A-4

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

ACS510-01-180A-4

ACS510-01-180A-4 cale of the whole system can be expanded. The hardware of the system control station is cfunction blocks. The function blocks provided by the system mainly include the following categories: o Analog processing o digital processing loop regulation Logical sequence control c logic operation Monitoring function Collection function. c arithmetic operations c TCP/IP protocol…

ACS510-01-195A-4

ACS510-01-195A-4as I/0 or field instruments) adopts the international standard field controller. Wire. The field controller supports various field buses such as Profibus. Profibus is the most widely used open field bus in the world. Line international standard, divided into FMS, DP and PA three levels, DP communication rate can be as high as 12Mb. The…