P0926JC

P0926JC distributed I/0 stations and field bus instruments. Communication between the process station, operator station and engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables and mixed media) and network topology can be selected for the system bus. Simple layout,…

P0926HZ

platform to ensure the system’s Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance. System engineering is very convenient. The configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram (LD), instruction list (IL), sequential function chart (SFC), structured text (ST)…

P0926HT

P0926HT (instructions): < 1.0 ms (processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard) Interface.   Basic characteristics: 1ee802.3 Ethernet standard o Ei801f provides 10base2…

P0926HM

P0926HM the The signals of the field bus sensors are processed according to the control application program configured by the user, and then the calculation results are passed The fieldbus interface card returns the corresponding fieldbus actuator. Two field controllers can realize controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on…

P0926HJ

P0926HJ provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is easy to replace and plug and play (plug & play) and can be…

P0926HF

P0926HF scale has strong scalability. The single system supports 1 to 100 control stations and 100 operation stations at most. Each control The station can support thousands of i/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is all metal enclosure, which can…

P0926HC

P0926HC intermittent control functions. The internal communication of the process control station (between the controller and various intelligent devices such as i/0 or field instruments) adopts the international standard field general Line. The field controller supports various field buses such as PROFIBUS, which is the most widely used open field bus in the world Line…

P0926CP ZCP270

P0926CP ZCP270 as I/0 or field instruments) adopts the international standard field controller. Wire. The field controller supports various field buses such as Profibus. Profibus is the most widely used open field bus in the world. Line international standard, divided into FMS, DP Industrial “is a world leading all-round comprehensive open control system launched by…

P0922AE

P0922AE module types ●Search and display based on specific criteria ● Cross reference can be used in systems that use a large number of variables or process points Programs and drawings to quickly find the desired variable or process point within the scope noodle. ABB is the world’s largest in measurement and process automation One…

P0922AE

P0922AE engineering station and several operators stand. ControlBuilderF engineering station configures and adjusts the system Mode. Usually, we can use portable devices such as notebooks to The system is now configured in the office and on site. Operator-level PC Can also be used as an engineer station. Engineer standing during system uptime Intervals can be…