CR06200-000000

CR06200-000000 level and the process control level is realized by Di giNetS network (Industrial Ethernet/IEEE802.3 standard), Users can choose the communication transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application. The popular PC and MS_ Windows 2000 have been widely used in various fields all over…

E22SSLT-LNN-NS-04

E22SSLT-LNN-NS-04 configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other Redundant basic unit pm802f) and can be…

E33NRHA-LNN-NS-00

E33NRHA-LNN-NS-00 Profibus DP,up to 12 MBd Modbus RTU,1200 to 38. 4KBd Industrial” CAN I/0 Bus o  Open CAN -Bus,up to 1 MBd o Foundation Fieldbus H1 up to 31. 25KBd Foundation Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller…

AKM42E-EKGNR-01

AKM42E-EKGNR-01 is embedded with a fieldbus communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is…

51304453-100

51304453-100 communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network topology can be selected for the system bus Due to the adoption of tcp/ip protocol, the…

51304644-125

51304644-125 and maintenance. System engineering configuration is very convenient. The configuration language is based on ie0611313 industrial standard and provides function block diagram (FBD) and ladder diagram (LD), instruction list (IL), sequential function diagram (SFC), structured text (st) and other graphical configuration modes. The system contains about 220 functions The algorithm library of energy block,…

51401437-301

51401437-301 applications As an important member of industrial “family, AC800F system fully embodies industrial” initiated and led by ABB in technology Information technology) a new trend. The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is…

FF-SB12E04K-S2

FF-SB12E04K-S2 trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems. can. The process control stage realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control. Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between…

J-DIM00

J-DIM00 and quality from manufacture all the way to service. ABB automation early In 1990, it obtained the DQS certificate based on ISO9001 certification, EQnet quality based on ISO 9000/EN 29000 was subsequently achieved Certification. However, the Freelance 800F is more than technical excellence, I We have also spent a lot of effort in proper…

TC-CCR014

TC-CCR014 configures and adjusts the system Mode. Usually, we can use portable devices such as notebooks to The system is now configured in the office and on site. Operator-level PC Can also be used as an engineer station. Engineer standing during system uptime Intervals can be closed without a permanent connection to the system. Freelance…