XYCOM IC1 500T-ABNOS06

XYCOM IC1 500T-ABNOS06 unified global database is used for the entire control system, thereby reducing cost and time investment in establishing data communication and interactive access. And ensure the consistency of data throughout the system. ●Provide system-wide unified inspection of user applications, overriding from process control stations, operator stations to intelligent field devices, including Including…

XYCOM PM4153B

XYCOM PM4153B convenient o Allowable operating ambient temperature…60 C, with automatic temperature monitoring o EMC (Electromagnetic Compatibility) according to EN50082 mouth Certifications: CE, NAMUR, CSA, CSA-NRT Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration.…

XYCOM PM9403R

XYCOM PM9403R Industrial” system through the ModBus protocol interface. The system also supports IEC870-5 over-control protocol. discussion. The Flash EPROM inside the PS provides more than 220 functional modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard In addition to this content, many powerful and rigorously tested…

XICOM PM9450

XICOM PM9450 system supports 1 to a maximum of 100 control stations and 100 operating stations. each control The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is encapsulated in an all-metal shell, which can withstand the…

XYCOM FM9485

XYCOM FM9485 process control station The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured -Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly. S800 and…

XYCOM PM9487T

XYCOM PM9487T configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard) Interface. Basic characteristics:…

XYCOM SXT1811T

XYCOM SXT1811T fi810f/fi820f/fi830f Various accessories The main components of the field controller PS are described below. Basic unit pm802f The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the The signals of the field bus sensors are processed according to the control application program…

xYCom SXT1811T-A

xYCom SXT1811T-A interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is easy to replace and plug and play (plug & play) and can be plugged in and out with power. The field controller PS has the…

XYCOM XVME-100

XYCOM XVME-100 Industria1 “system communication Industrial ial “the system uses the international standard industrial bus. The field controller supports PROFIBUS, FF, MODBUS, can and other countries International standard fieldbus, PROFIBUS is the most widely used open fieldbus international standard in the world, which is divided into FMS, DP and pa Level III, DP communication rate…

XYCOM XVME -230

XYCOM XVME -230XYCOM XVME -230 system hardware diagnosis and data exchange between different systems Yes. The process control level realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between the controller and…