1C31116G04

process control stations connected to I/O units. you can choose this Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field device…

5X00070G04

keyboard. Operator level can install one engineering station and several operators stand. ControlBuilderF engineering station configures and adjusts the system Mode. Usually, we can use portable devices such as notebooks to The system is now configured in the office and on site. Operator-level PC Can also be used as an engineer station. Engineer standing during…

1C31132G01

by means of GSD file import PROFIBUS-DP and PA devices, and through user-defined pairing dialog box to design the configuration window for these devices. ●Profibus field controller can be integrated through FDT/DTM technology line equipment   system structure The Freelance 800F process control system is divided into operator levels and process control level. The operator…

1C31129G03

and interactive access. And ensure the consistency of data throughout the system. ●Provide system-wide unified inspection of user applications, overriding from process control stations, operator stations to intelligent field devices, including Including the integrity and consistency check of the user program. ●The programming language strictly complies with the international standard of IEC61131-3, and has There…

1C31238H01

migration of cost structure creates a lot of innovation for users. Create an opportunity to optimize project investment, therefore, it is necessary to start from engineering programming Think about lowering costs in the first place! This is what we developed the Freelance 800F system for: Keeping hardware prices consistent with those of programmable logic controllers…

1C31234G01

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

1C31181G02

is simple and convenient o Allowable operating ambient temperature 60 C, automatic temperature monitoring o EMC (electromagnetic compatibility) conforms to en50082 standard mouth Certification: CE, Namur, CSA, csa-nrtl, FM class 1 div2, ghost, Lloyd Installation area: Class 1 div 2 The PS supports the following types of fieldbus standards: Profibus DP,up to 12 MBd Modbus…

1C31179G02

diagnostic information from the bus. The interface card is easy to replace and plug and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected…

1C31181G01

control All schemes can be realized by the combination of these function blocks. The function blocks provided by the system mainly fall into the following categories: o Analog quantity processing o Digital quantity processing Loop adjustment Logical sequence control c Logical operation Monitoring function Acquisition function c Arithmetic operation c Tcp/ip protocol communication interface Modbus…

1C31179G01

which is divided into FMS, DP and pa Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission…