blocks. The function blocks provided by the system mainly include the following categories: o Analog processing o digital processing loop regulation Logical sequence control c logic operation Monitoring function Collection function. c arithmetic operations c TCP/IP protocol communication interface Modbus protocol communication interface 1EC870-5 protocol communication interface (Telecontrol) 4.2 Field Controller PS Industrial” field controller…

5X00502G01

divided into FMS, DP and PA Level 3, DP communication rate can be as high as 12Mb. Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus instruments. Communication between the process station, operator station and engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission…

5X00501G01

Harsh industrial environment. The device can be installed either in a cabinet or on a wall. System complies with all current EMC standards and is CE marked Chi. Industrial” DCS system design purpose: the most economical engineering investment, the most powerful control function. Five features of Industria1″ DCS system: 1. All-round integrated control system, integrating…

5X00321G01

The configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram (LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions Algorithm library for energy blocks and a basic library with more than 200 graphic symbols…

5X00300G01

biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through IART protocol or field bus (31. 25Kb ProfibusPA and FF bus). The system communication between the operation management level and the process control level is realized by Di giNetS network…

5X00497G01

two serial interfaces are provided to connect the serial protocol equipment. The maximum transmission rate is 38.4kbd and can be configured. Its Standards Association Modbus Different physical interfaces can be selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation Away. And the redundant operation is realized by two redundant field controllers.…

5X00327G01

replacement card fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed…

5X00301G01

optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network…

5X0026144G01

configuration and PS The user program is downloaded to the PS CPU through diginets and the first network card. After the field bus interface card is newly installed or replaced, the required group The status information will be automatically reloaded. The configuration results and real-time process data are stored in RAM, and ram is installed…

5X00226G03

controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special Redundant communication link (diginetr) to ensure information synchronization between master…