IS200EPSMG1A

AUI, twisted pair, fiber optic or coaxial cable. Freelance OPC server for connecting to higher-level operators station (800xA) or other OPC client. Freelance Control System Real-time process values ??and alarms in the system can be accessed via OPC. We also provide a C language programming interface to embed external In Windows operating system applications, it…

DO810

Usually, we can use portable devices such as notebooks to The system is now configured in the office and on site. Operator-level PC Can also be used as an engineer station. Engineer standing during system uptime Intervals can be closed without a permanent connection to the system. Freelance 800F Process Control Stage At the process…

DI803

structure The Freelance 800F process control system is divided into operator levels and process control level. The operator level contains controls for operation and display. Archiving and logging, trending and alarming functions. Controller executes open loop and closed loop control function. Freelance 800F DigiVis Operator Level DigiVis operator stations use PC hardware, either standard commercial…

DI802

●Provide system-wide unified inspection of user applications, overriding from process control stations, operator stations to intelligent field devices, including Including the integrity and consistency check of the user program. ●The programming language strictly complies with the international standard of IEC61131-3, and has There are high-performance graphics editing functions: – Function Block Diagram (FBD) -Ladder Diagram…

DI801

migration of cost structure creates a lot of innovation for users. Create an opportunity to optimize project investment, therefore, it is necessary to start from engineering programming Think about lowering costs in the first place! This is what we developed the Freelance 800F system for: Keeping hardware prices consistent with those of programmable logic controllers…

DI890

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

DI885

fieldbuses and can be mixed Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd) Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field including equipment management information Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage…

DI840

categories: o Analog processing o digital processing loop regulation Logical sequence control c logic operation Monitoring function Collection function. c arithmetic operations c TCP/IP protocol communication interface Modbus protocol communication interface 1EC870-5 protocol communication interface (Telecontrol) 4.2 Field Controller PS Industrial” field controller PS is a special process control station, which is embedded with field…

DI831

layout, due to the use of TCP/IP protocol, the system can also use the public telephone network (dial-up mode) or satellite to achieve ultra-long-distance communication. Subsystems such as PLC communicate with the Industrial” system through the ModBus protocol interface. The system also supports IEC870-5 over-control protocol. discussion. The Flash EPROM inside the PS provides more…

D1830

high-speed CPU, with super performance; Three high reliability, strict industrial application practice, more than 1000 sets of application performance in China; 4. It has good openness, flexibility and scalability; Fifth, the project is easy, the interface is friendly, and the maintenance is simple; 2. Industria1″ system communication Industrial” system uses international standard industrial bus. Field…