P0923VD

rate can be as high as 12Mb. Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus instruments. Communication between the process station, operator station and engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables…

P0923VA

stations and 100 operating stations. each control The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is encapsulated in an all-metal shell, which can withstand the most Harsh industrial environment. The device can be installed either in…

P0923QY

medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application. The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform. tower. The operating station 0S, the engineering station ES and the data gateway…

PO923QX

information technology) new trends. The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is realized function (operation and display, printing, trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems.…

P0923QW

maintenance faster, more economical and more efficient. Industrial” is a world-leading all-round integrated open control system launched by ABB Group Automation Headquarters. It integrates the advantages of traditional DCS and PLC in one body and supports a variety of international field bus standards. It has both the complex analog loop regulation capability of DCS Power-friendly…

P0923QV

system’s public database for management. ● List of all variables (input, output, internal variables) ● Process point list (function block) ●Graphics ●Program Because the database is system-wide. The data only needs to enter a times, to avoid possible errors caused by multiple configurations. Project database files can be easily archived or backed up. When programmed…

P0923QT

control level, the Freelance 800F system can be controlled by It consists of a number of process control stations connected to I/O units. you can choose this Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to…

P0923QS

alarming functions. Controller executes open loop and closed loop control function. Freelance 800F DigiVis Operator Level DigiVis operator stations use PC hardware, either standard commercial Business PCs can also be industrial-grade PCs and run on Micro- under soft Windows operating system. DigiVis supports dual-screen display operation operating technology, that is to say, two operations can…

P0923QM

process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment in establishing data communication and interactive access. And ensure the consistency of data throughout the system. ●Provide system-wide unified inspection of user applications, overriding from process control stations, operator stations to intelligent…

P0923QL

investment of modern automation system, due to the hardware equipment department It only takes up less cost in the whole system, then write engineering applications The cost of software becomes increasingly important. Generally speaking, a self The engineering application software cost of the automation project accounts for about the entire project. About 50%, it is…