ABB KUC711AE 3BHB004661R0001

level, operation level and even fieldbus instruments, and uses the same A global database. The system scale has strong scalability. The single system supports 1 to 100 control stations and 100 operation stations at most. Each control The station can support thousands of i/0 points at most, and the scale of the whole system can…

ABB KUC711AE101 3BHB004661R0101

communication transmission medium (ordinary cable or optical fiber) and network topology structure according to the actual situation of the application. Popular PC and MS_ Wi ndows2000 has been widely used in various fields all over the world and has become the de facto standard computer platform Set. The operating station 0s, engineer station es and…

ABB KUC711AE01 3BHB004661R0001

led by ABB in technology Information technology) a new trend. The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is realized Can (operate and display, print, trend display and alarm), and also complete system hardware diagnosis…

5102-MBS3-MBM PROSOFT

various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control. Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between the controller and various intelligent devices such as I/0 or field instruments) adopts the international standard field controller. Wire. The field controller supports…

5305-MBP-PDPS PROSOFT

and convenient engineering software, and at the same time have high-speed logic and sequence control equivalent to high-end PLC indicators. control performance. The system can be connected to both conventional I/0 and various field bus devices such as Profibus, FF, CAN, and Modbus. system tool It has a high degree of flexibility and excellent scalability,…

3150-MCM PROSOFT

of variables and labels is automatically created. Moreover, both variables and process points can be opened and closed directly in FBD or IL Revise. List other features include: Project-wide modification of names, comments, data or module types ●Search and display based on specific criteria ● Cross reference can be used in systems that use a…

5304-MBP-PDPM PROSOFT

Communication between operator level and process control level using TCP/IP Protocol system bus (based on Ethernet), you can choose different transmission medium such as AUI, twisted pair, fiber optic or coaxial cable. Freelance OPC server for connecting to higher-level operators station (800xA) or other OPC client. Freelance Control System Real-time process values ??and alarms in…

5302-MBP-MCM4 PROSOFT

field controller can be integrated through FDT/DTM technology line equipment   system structure The Freelance 800F process control system is divided into operator levels and process control level. The operator level contains controls for operation and display. Archiving and logging, trending and alarming functions. Controller executes open loop and closed loop control function. Freelance 800F…

5304-MBP-PDPM PROSOFT

function, operator interface display and logging, and configuration of the fieldbus. equipment (PROFIBUS, FOUNDATION Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station and the operator station According to communication. 版权归千图网所有,盗图必究   For field devices, process control stations and operator stations, a unified global database is…

MVI56-MCMR PROSOFT

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…