VE4050S2K1C1

controllers. Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured -Block fi810f…

VE4014

communication interface 32-bit data bus, 100 mb/s   DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4% Optional ram backup battery Fieldbus interface replacement card fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS,…

VE4001S2T1B1

the first network card. After the field bus interface card is newly installed or replaced, the required group The status information will be automatically reloaded. The configuration results and real-time process data are stored in RAM, and ram is installed on the Ethernet network card or battery card The backup battery can maintain the configuration…

VE4011B1

card ei801f/ei802f/ei803f o Fieldbus interface card fi810f/fi820f/fi830f Various accessories The main components of the field controller PS are described below. Basic unit pm802f The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the The signals of the field bus sensors are processed according to…

VE4003S1B2

Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is easy to replace and plug and play (plug & play) and can…

VE4010B1

international standard in the world, which is divided into FMS, DP and pa Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets…

VE4050S2K1CO

process level, operation level and even fieldbus instruments, and uses the same A global database. The system scale has strong scalability. The single system supports 1 to 100 control stations and 100 operation stations at most. Each control The station can support thousands of i/0 points at most, and the scale of the whole system…

VE4002S1T1B1

can be as high as 12MB. Can (din/is011898 standard) bus The biggest feature is its super robustness and data security. The system also supports MODBUS. The communication with intelligent field instruments is through IART protocol or fieldbus (31.25kb profibuspa and FF Bus). The system communication between the operation management level and the process control level…

VE4O36P2

system can connect not only conventional i/0, but also PROFIBUS, FF, can, MODBUS and other field bus devices. System tool It has high flexibility and excellent scalability, whether it is the control of small-scale production devices or the large-scale integrated control of the whole plant, even The industrial “system can cope with the field equipment…

VE5001

new trends. The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is realized function (operation and display, printing, trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems. can. The…