662 DSC

opportunity to optimize project investment, therefore, it is necessary to start from engineering programming Think about lowering costs in the first place! This is what we developed the Freelance 800F system for: Keeping hardware prices consistent with those of programmable logic controllers In this way, cost efficiency can be improved by reducing user engineering costs.…

UNI DSC

controller PS has the following characteristics: o Flexible: supports all international standard open fieldbuses and can be mixed Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd) Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field including equipment management information…

HE10-20 DSC

cables and mixed media) and network topology can be selected for the system bus. Simple layout, due to the use of TCP/IP protocol, the system can also use the public telephone network (dial-up mode) or satellite to achieve ultra-long-distance communication. Subsystems such as PLC communicate with the Industrial” system through the ModBus protocol interface. The…

LAF100 DSC

fieldbus instruments, and uses the same a global database. The scale of the system is highly scalable, and a single-system supports 1 to a maximum of 100 control stations and 100 operating stations. each control The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded.…

XC32L2 DSC

high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through IART protocol or field bus (31. 25Kb ProfibusPA and FF bus). The system communication between the operation management level and the…

XC32L1 DSC

“unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other Redundant basic unit pm802f) and can be plugged in and out and replaced online. Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach…

XE08B5 DSC

card Support hot plug of Fieldbus interface card Technical indicators of basic unit pib02f: CPU :Intel 80960HT25/75 32-bit RISC superscalar processor with operation speed of 150 MIPS 4 MB FLASH-EPROM EEPROM,serial, 16 Kbit o Ram 8 MB (with error check and correction function, abb patent) 16 K internal cache (CPU cache RAM) Ram backup battery…

XM06B5 DSC

Foundation Fieldbus H1 up to 31. 25KBd Foundation Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS. Industrial “field control explosion (AC800F) consists of the following components: Basic unit pm802f Power supply sa801f/sd802f o Ethernet network card ei801f/ei802f/ei803f o…

XO08R2 DSC

station, which is embedded with a fieldbus communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card…

XO08Y1 DSC

stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network topology can be selected for the system bus…