07SK50

archived or backed up. When programmed by the user, a list of variables and labels is automatically created. Moreover, both variables and process points can be opened and closed directly in FBD or IL Revise. List other features include: Project-wide modification of names, comments, data or module types ●Search and display based on specific criteria…

AC31GRAF

Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field device via fieldbus ready. system communication Communication between operator level and process…

XE08B5

Structured Text (ST) ●Extensive function block library, user-defined function blocks can also be added Added to it, the macro library and graphic symbols can be customized for the user. Blocks can create graphics and operator panels. ●Any standard can be integrated by means of GSD file import PROFIBUS-DP and PA devices, and through user-defined pairing…

XO16N1

equipment (PROFIBUS, FOUNDATION Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station and the operator station According to communication.   For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment…

XK08F1

Automatic generation of global data between the process control station and the operator station According to communication. For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment in establishing data communication and interactive access. And ensure the consistency of…

XC08L1

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

XO08Y1 DSC

divided into FMS, DP and PA Level 3, DP communication rate can be as high as 12Mb. Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus instruments. Communication between the process station, operator station and engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission…

XO16N1 DSC

function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions Algorithm library for energy blocks and a basic library with more than 200 graphic symbols and an extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete…

XC08L1 DSC

controllers. Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured -Block fi810f…

XK08F1 DSC

communication interface 32-bit data bus, 100 mb/s DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4% Optional ram backup battery 版权归千图网所有,盗图必究 Fieldbus interface replacement card fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS,…