XYCOM XYCOM 3510

XYCOM XYCOM 3510 station consists of 2 AC800F controller. Rack mounted process station: This term is used to describe a rack-mounted type of process station. A redundant process station contains 2 rack-mounted CPUs. This term is used to describe a single, non-redundant process station. In the investment of modern automation system, due to the hardware…

Details

XYCOM XYCOM 2060

XYCOM XYCOM 2060 design purpose: the most economical engineering investment, the most powerful control function. Five features of Industria1″ DCS system: 1. All-round integrated control system, integrating DCS & PLC & Field Bus; 2. Using RISC SuperScalar high-speed CPU, with super performance; Three high reliability, strict industrial application practice, more than 1000 sets of application…

Details

XYCOM XYCOM 2050

XYCOM XYCOM 2050 language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram (LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions Algorithm library for energy blocks and a basic library with more than 200 graphic…

Details

XYCOM XYCOM 2005

XYCOM XYCOM 2005 can only be configured -Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly. S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus Communication, which can be installed in the controland PA three levels, DP…

Details

XYCOM XYCOM 2000

XYCOM XYCOM 2000 communication with the system network diginet s (iee802.3 Ethernet standard) Interface.   Basic characteristics: 1ee802.3 Ethernet standard o Ei801f provides 10base2 thin cable communication interface Ei802f provides 10BASE5 thick cable connection (through AUI interface) Ei803f provides 10Base-T twisted pair communic  ation interface 32-bit data bus, 100 mb/s DMA (direct memory access) mode…

Details

XYCOM XYCOM 1840

XYCOM XYCOM 1840 returns the corresponding fieldbus actuator. Two field controllers can realize controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to…

Details

XYCOM XVME-9403

XYCOM XVME-9403 interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is easy to replace and plug and play (plug & play) and can be plugged in and out with power. The field controller PS has the…

Details

XYCOM 09S-3MX

XYCOM 09S-3MX III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin cable, thick…

Details

XYCOM 69S-3MAX

XYCOM 69S-3MAX configuration language is based on ie0611313 industrial standard and provides function block diagram (FBD) and ladder diagram (LD), instruction list (IL), sequential function diagram (SFC), structured text (st) and other graphical configuration modes. The system contains about 220 functions The algorithm library of energy block, the basic library with more than 200 graphic…

Details

XYCOM 999-TNhX

XYCOM 999-TNhX control level realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control Control, sequence control and batch intermittent control functions. The internal communication of the process control station (between the controller and various intelligent devices such as i/0 or field instruments) adopts the international standard field general…

Details