TRICONEX4210

Mode. Usually, we can use portable devices such as notebooks to The system is now configured in the office and on site. Operator-level PC Can also be used as an engineer station. Engineer standing during system uptime Intervals can be closed without a permanent connection to the system. Freelance 800F Process Control Stage At the…

Details

TRICONEX4211

Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station and the operator station According to communication.     For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment in establishing…

Details

TRICONEX3721

Wiring DIN rail (U-shaped) installation well can be directly wall mounted, simple and convenient o Allowable operating ambient temperature…60 C, with automatic temperature monitoring o EMC (Electromagnetic Compatibility) according to EN50082 mouth Certifications: CE, NAMUR, CSA, CSA-NRT Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process…

Details

TRICONEX3805E

expanded. any complex control The scheme can be realized by the combination of these function blocks. The function blocks provided by the system mainly include the following categories: o Analog processing o digital processing loop regulation Logical sequence control c logic operation Monitoring function Collection function. c arithmetic operations c  TCP/IP protocol communication interface Modbus…

Details

TRICONEX 3511

encapsulated in an all-metal shell, which can withstand the most Harsh industrial environment. The device can be installed either in a cabinet or on a wall. System complies with all current EMC standards and is CE marked Chi.  Industrial” DCS system design purpose: the most economical engineering investment, the most powerful control function. Five features…

Details

TRICONEX3625

biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through IART protocol or field bus (31. 25Kb ProfibusPA and FF bus). The system communication between the operation management level and the process control level is realized by Di giNetS network…

Details

TRICONEX3604E

communication interface Ei802f provides 10BASE5 thick cable connection (through AUI interface) Ei803f provides 10Base-T twisted pair communication interface 32-bit data bus, 100 mb/s DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4% Optional ram backup battery Fieldbus interface replacement card fi830f/fi820f/fi810f Fieldbus interface cards are divided into several types according to…

Details

TRICONEX3664

slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation.   The data communication between the field process controller PS. operating station 0s and the engineer station es is completed by the system network (diginets), which is inserted The – Ethernet network card on the PS…

Details

TRICONEX 4211

international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the same tool CBF (control build f) software for configuration, debugging and diagnosis mouth Access to all information from the site, including equipment management information Global database of Fieldbus equipment,…

Details

TRICONEX 8112

protocol, the system can also realize ultra long distance communication with the help of public telephone network (dial-up mode) or satellite. PLC and other subsystems communicate with industrial “system through Modbus protocol interface. The system also supports iec870-5 over control coordination Discussion.   The flash EPROM inside PS provides more than 220 function modules (control…

Details