AI625

AI625 and a single-system supports 1 to a maximum of 100 control stations and 100 operating stations. each control The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is encapsulated in an all-metal shell, which can withstand…

Details

GD9924BE/V2

GD9924BE/V2supports Modbus. The communication with the intelligent field instrument is through IART protocol or field bus (31. 25Kb ProfibusPA and FF bus). The system communication between the operation management level and the process control level is realized by Di giNetS network (Industrial Ethernet/IEEE802.3 standard), Users can choose the communication transmission medium (ordinary cable or optical…

Details

DP820

DP820Automation Headquarters. It integrates the advantages of traditional DCS and PLC in one body and supports a variety of international field bus standards. It has both the complex analog loop regulation capability of DCS Power-friendly human-machine interface (HMI) and convenient engineering software, and at the same time have high-speed logic and sequence control equivalent to…

Details

IP-QUADRATURE

IP-QUADRATURE transmission medium such as AUI, twisted pair, fiber optic or coaxial cable. Freelance OPC server for connecting to higher-level operators station (800xA) or other OPC client. Freelance Control System Real-time process values ??and alarms in the system can be accessed via OPC. We also provide a C language programming interface to embed external In…

Details

SPBLK01

SPBLK01 in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field lay. Archiving and logging, trending and alarming functions. Controller executes open loop and closed loop…

Details

086370-001

086370-001 devices, and through user-defined pairing dialog box to design the configuration window for these devices. ●Profibus field controller can be integrated through FDT/DTM technology line equipment system structure The Freelance 800F process control system is divided into operator levels and process control level. The operator level contains controls for operation and display. Archiving and…

Details

CSG-25-80-2A-GR-SP

CSG-25-80-2A-GR-SP logging, and configuration of the fieldbus. equipment (PROFIBUS, FOUNDATION Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station and the operator station According to communication.     For field devices, process control stations and operator stations, a unified global database is used for the entire…

Details

IC694ALG392

IC694ALG392 installation well can be directly wall mounted, simple and convenient o Allowable operating ambient temperature…60 C, with automatic temperature monitoring o EMC (Electromagnetic Compatibility) according to EN50082 mouth Certifications: CE, NAMUR, CSA, CSA-NRT Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be…

Details

XXD129A01

XXD129A01 operator station and engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables and mixed media) and network topology can be selected for the system bus. Simple layout, due to the use of TCP/IP protocol, the system can also use…

Details

CSF-40B-160-MSP178

CSF-40B-160-MSP178 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform to ensure the system’s Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance. System engineering is very convenient. The configuration language is based on the IE061131 3 industry standard, providing…

Details