5A22727G02

controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special Redundant communication link (diginetr) to ensure information synchronization between master…

Details

5A22412H01

sa801f/sd802f o Ethernet network card ei801f/ei802f/ei803f o Fieldbus interface card fi810f/fi820f/fi830f Various accessories The main components of the field controller PS are described below. Basic unit pm802f The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the The signals of the field bus sensors…

Details

5A22411H01

operating parameters c Complete self diagnosis Compact and rugged design Front panel wiring DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient   o Allowable operating ambient temperature 60 C, automatic temperature monitoring o EMC (electromagnetic compatibility) conforms to en50082 standard mouth Certification: CE, Namur, CSA, csa-nrtl,…

Details

5A22410H02

and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the same tool…

Details

5A22410H01

Tcp/ip protocol communication interface Modbus protocol communication interface 1ec870-5 protocol communication interface (telecontrol) 4.2 field controller PS Industrial ial “field controller PS is a special process control station, which is embedded with a fieldbus communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus…

Details

4D33945G01

through Modbus protocol interface. The system also supports iec870-5 over control coordination Discussion.   The flash EPROM inside PS provides more than 220 function modules (control algorithm subroutines), in addition to the base specified in IEC 61131 3 standard In addition to this content, many powerful and strictly tested function blocks from practical engineering applications…

Details

4D33942G02

12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network…

Details

4D33942G01

system: 1、 The comprehensive control system integrates DCS & PLC & field bus; 2、 RISC superscalar high-speed CPU with super performance; 3. High reliability, strict industrial application practice, and application performance of more than 1000 sets in China; 4、 Good openness, flexibility and expansibility; 5、 Easy engineering, friendly interface and simple maintenance; 2. Industria1 “system…

Details

4D33935H01

level, operation level and even fieldbus instruments, and uses the same A global database. The system scale has strong scalability. The single system supports 1 to 100 control stations and 100 operation stations at most. Each control The station can support thousands of i/0 points at most, and the scale of the whole system can…

Details

4D33934G01

thus ensuring the It is universal, open and easy to use, and brings great convenience for future technology upgrading and maintenance. System engineering configuration is very convenient. The configuration language is based on ie0611313 industrial standard and provides function block diagram (FBD) and ladder diagram (LD), instruction list (IL), sequential function diagram (SFC), structured text…

Details