5X00058G01

instruments, and uses the same a global database. The scale of the system is highly scalable, and a single-system supports 1 to a maximum of 100 control stations and 100 operating stations. each control The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded. The…

Details

5X00501G01

Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform. tower. The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform to ensure the system’s Versatility, openness and ease of use, and bring great convenience…

Details

5X00034G01

PS can only be configured -Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly. S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus Communication, which can be installed in the controland PA three levels, DP communication rate…

Details

1C31227G02

two serial interfaces are provided to connect the serial protocol equipment. The maximum transmission rate is 38.4kbd and can be configured. Its Standards Association Modbus Different physical interfaces can be selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation Away. And the redundant operation is realized by two redundant field controllers.…

Details

5X00070G02

types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS, Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the industrial “unified tool control bui lder without additional…

Details

1C31227G02

cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16 bit arithmetic instructions) <2ms (processing fixed-point arithmetic instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard) Interface. Basic characteristics: 1ee802.3…

Details

5X00070G03

configuration results and real-time process data are stored in RAM, and ram is installed on the Ethernet network card or battery card The backup battery can maintain the configuration content and data in case of power failure. Basic unit pmbo2f characteristics: mouth Installation slots of 4 fieldbus interface cards c Installation slot of 2 Ethernet…

Details

1C31116G05

to form a special Redundant communication link (diginetr) to ensure information synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation.   The data communication between the field process controller PS. operating…

Details

5X00070G05

sa801f/sd802f o Ethernet network card ei801f/ei802f/ei803f o Fieldbus interface card fi810f/fi820f/fi830f Various accessories The main components of the field controller PS are described below. Basic unit pm802f The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the The signals of the field bus sensors…

Details

5X00375G01

control level and HMI (human-machine interface) Module identification with production operating parameters c Complete self diagnosis Compact and rugged design Front panel wiring DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient   o Allowable operating ambient temperature 60 C, automatic temperature monitoring o EMC (electromagnetic compatibility)…

Details