JANCD-TU02B

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

Details

JANCD-CG23

the following characteristics: o Flexible: supports all international standard open fieldbuses and can be mixed Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd) Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field including equipment management information Global database of…

Details

JANCD-GMM22

modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control The scheme can be realized by the combination of these function blocks. The function blocks provided…

Details

YASKAWA-JANCD-MB21-BOARD-DF8101521-CO-REV-C

high-speed CPU, with super performance; Three high reliability, strict industrial application practice, more than 1000 sets of application performance in China; 4. It has good openness, flexibility and scalability; Fifth, the project is easy, the interface is friendly, and the maintenance is simple; 2. Industria1″ system communication Industrial” system uses international standard industrial bus. Field…

Details

JANCD-SV028

library with more than 200 graphic symbols and an extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete the configuration and debugging of process level, operation level and even fieldbus instruments, and uses the same a global database. The scale of the system…

Details

JANCD-I003D

biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through IART protocol or field bus (31. 25Kb ProfibusPA and FF bus). The system communication between the operation management level and the process control level is realized by Di giNetS network…

Details

JANCD-CG03

trends. The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is realized function (operation and display, printing, trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems. can. The process…

Details

JANCD-XCP03

in proper planning, installation and revision too This makes engineering design and maintenance faster, more economical and more efficient. Industrial” is a world-leading all-round integrated open control system launched by ABB Group Automation Headquarters. It integrates the advantages of traditional DCS and PLC in one body and supports a variety of international field bus standards.…

Details

JANCD-MMOIC

block) ●Graphics ●Program Because the database is system-wide. The data only needs to enter a times, to avoid possible errors caused by multiple configurations. Project database files can be easily archived or backed up. When programmed by the user, a list of variables and labels is automatically created. Moreover, both variables and process points can…

Details

JANCD-XSL02

stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field device via fieldbus ready. system communication Communication between operator level and process control level…

Details