SCHNEIDER 140SDI95300S

than 200 graphic symbols and an extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete the configuration and debugging of process level, operation level and even fieldbus instruments, and uses the same a global database. The scale of the system is highly scalable,…

Details

SCHNEIDER 140SAI94000S

transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application. The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform.   tower. The operating station 0S, the engineering station ES and the…

Details

SCHNEIDER 140CPU67160S

  process control station The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured -Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly. S800 and S900…

Details

SCHNEIDER 140CPU65160S

(separated between each other Redundant basic unit pm802f) and can be plugged in and out and replaced online. Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd One PS can plug in 4 fieldbus interfaces, connect 496 fieldbus devices, and one…

Details

SCHNEIDER 140N0C77100

instructions) < 1.5ms (processing 32-bit floating-point arithmetic instructions) Bthernet network card ei801f/ei802f/ei803f The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard) Interface. Basic characteristics: 1ee802.3 Ethernet standard o Ei801f provides 10base2 thin cable communication interface Ei802f provides 10BASE5 thick cable connection (through AUI interface) Ei803f provides 10Base-T twisted…

Details

SCHNEIDER 140ESI06210

required group The status information will be automatically reloaded. The configuration results and real-time process data are stored in RAM, and ram is installed on the Ethernet network card or battery card The backup battery can maintain the configuration content and data in case of power failure. Basic unit pmbo2f characteristics: mouth Installation slots of…

Details

SCHNEIDER 140N0C77100

the user, and then the calculation results are passed The fieldbus interface card returns the corresponding fieldbus actuator. Two field controllers can realize controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the…

Details

SCHNEIDER 140ESI06210

identification with production operating parameters c Complete self diagnosis Compact and rugged design Front panel wiring DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient   o Allowable operating ambient temperature 60 C, automatic temperature monitoring o EMC (electromagnetic compatibility) conforms to en50082 standard mouth Certification: CE,…

Details

SCHNEIDER 140NOA62200

controller PS Industrial ial “field controller PS is a special process control station, which is embedded with a fieldbus communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is connected to a fieldbus to…

Details

SCHNEIDER 1407M10000

of public telephone network (dial-up mode) or satellite. PLC and other subsystems communicate with industrial “system through Modbus protocol interface. The system also supports iec870-5 over control coordination Discussion. The flash EPROM inside PS provides more than 220 function modules (control algorithm subroutines), in addition to the base specified in IEC 61131 3 standard In…

Details