TC-CCR013

maintaining this market position is the quality of our products quantity, and quality from manufacture all the way to service. ABB automation early In 1990, it obtained the DQS certificate based on ISO9001 certification, EQnet quality based on ISO 9000/EN 29000 was subsequently achieved Certification. However, the Freelance 800F is more than technical excellence, I…

Details

TC-CCH013

suitable for implementing user Communicate with non-standard OPC, ie DMS-API software package. Project database All configured signals, variables and process points are in Freelance 800F system’s public database for management. ● List of all variables (input, output, internal variables) ● Process point list (function block) ●Graphics ●Program Because the database is system-wide. The data only…

Details

TK- PRS021

control level, the Freelance 800F system can be controlled by It consists of a number of process control stations connected to I/O units. you can choose this Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy redundant) or non-redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to…

Details

DRIVE 51196929-135

equipment system structure The Freelance 800F process control system is divided into operator levels and process control level. The operator level contains controls for operation and display. Archiving and logging, trending and alarming functions. Controller executes open loop and closed loop control function. Freelance 800F DigiVis Operator Level DigiVis operator stations use PC hardware, either…

Details

DRIVE 51109701-100

Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station and the operator station According to communication.   For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment in establishing data…

Details

DRIVE 51197012-100

engineering applications The cost of software becomes increasingly important. Generally speaking, a self The engineering application software cost of the automation project accounts for about the entire project. About 50%, it is not difficult to see that the migration of cost structure creates a lot of innovation for users. Create an opportunity to optimize project…

Details

CABLES 51 190896-100

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F :  This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

Details

OUTPUT 51303985-300

Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack…

Details

SUPPLY 51195066-200

communication interface for users to use Fieldbus technology offers very flexible options. Each PS allows to insert 4 fieldbus interface cards (the card type can be different), Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and…

Details

MCPI 51109919-100

achieve ultra-long-distance communication. Subsystems such as PLC communicate with the Industrial” system through the ModBus protocol interface. The system also supports IEC870-5 over-control protocol. discussion.  The Flash EPROM inside the PS provides more than 220 functional modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard In addition…

Details