JANCD-MM02

process data are stored in RAM, and ram is installed on the Ethernet network card or battery card The backup battery can maintain the configuration content and data in case of power failure. Basic unit pmbo2f characteristics: mouth Installation slots of 4 fieldbus interface cards c Installation slot of 2 Ethernet network cards Support redundant…

Details

JANCD-FC222

redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special Redundant communication link (diginetr) to ensure information synchronization between master and slave…

Details

JANCD-CG

compatibility) conforms to en50082 standard mouth Certification: CE, Namur, CSA, csa-nrtl, FM class 1 div2, ghost, Lloyd Installation area: Class 1 div 2 The PS supports the following types of fieldbus standards: Profibus DP,up to 12 MBd Modbus RTU,1200 to 38. 4KBd Industrial” CAN I/0 Bus o Open CAN -Bus,up to 1 MBd o Foundation…

Details

jancd-cp01b

controller PS is a special process control station, which is embedded with a fieldbus communication interface for users to use Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different), Each card is connected to a fieldbus to collect process data and diagnostic…

Details

JANCD-MCP02

(RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network topology can be selected for the system bus Due to the adoption of tcp/ip protocol, the system can also realize ultra long distance communication with the help of public telephone network (dial-up mode) or satellite. PLC and other subsystems…

Details

DF9201012-CO

hardware of the system control station is all metal enclosure, which can withstand the most Harsh industrial environment. The equipment can be installed in the cabinet or on the wall. The system complies with all current EMC standards and has CE standards Annals. Industrial “DCS system design purpose: the most economical engineering investment and the…

Details

481658-94-0

graphical configuration modes. The system contains about 220 functions The algorithm library of energy block, the basic library with more than 200 graphic symbols and the extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete the configuration and commissioning of process level, operation…

Details

JANCD-XCP01C

member of industrial “family, AC800F system fully embodies industrial” initiated and led by ABB in technology Information technology) a new trend. The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is realized Can (operate and display,…

Details

JANCD-1

(between the controller and various intelligent devices such as I/0 or field instruments) adopts the international standard field controller. Wire. The field controller supports various field buses such as Profibus. Profibus is the most widely used open field bus in the world. Line international standard, divided into FMS, DP Industrial “is a world leading all-round…

Details

JANCD-FC100B

conventional I/0 and various field bus devices such as Profibus, FF, CAN, and Modbus. system tool It has a high degree of flexibility and excellent scalability, whether it is the control of small production units, or the control of ultra-large-scale whole plants – integrated control, even The Industrial” system can handle the application of field…

Details