00-108-548

Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus instruments. Communication between the process station, operator station and engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables and mixed media) and network topology can…

Details

00-108-313

hardware of the system control station is encapsulated in an all-metal shell, which can withstand the most Harsh industrial environment. The device can be installed either in a cabinet or on a wall. System complies with all current EMC standards and is CE marked Chi. Industrial” DCS system design purpose: the most economical engineering investment,…

Details

00-117-336

users reduce Low engineering cost? ●By using a complete engineering tool (Control Builder F) to configure the entire control system, including automation functions function, operator interface display and logging, and configuration of the fieldbus. equipment (PROFIBUS, FOUNDATION Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station…

Details

00-145-742

equipment department It only takes up less cost in the whole system, then write engineering applications The cost of software becomes increasingly important. Generally speaking, a self The engineering application software cost of the automation project accounts for about the entire project. About 50%, it is not difficult to see that the migration of cost…

Details

00-128-358

and convenient o Allowable operating ambient temperature…60 C, with automatic temperature monitoring o EMC (Electromagnetic Compatibility) according to EN50082 mouth Certifications: CE, NAMUR, CSA, CSA-NRT Glossary Process station: This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant configuration and non-redundant configuration. AC800F…

Details

00-125-236

different), Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and play (Plug & Play), and can be plugged and unplugged. The field controller PS has the following characteristics: o Flexible: supports all international standard open fieldbuses…

Details

00-108-766

the IEC 61131 3 standard In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control The scheme can be realized by the combination of these function blocks. The function blocks provided by the system mainly include the following categories: o Analog processing o…

Details

00-111-230

user Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables and mixed media) and network topology can be selected for the system bus. Simple layout, due to the use of TCP/IP protocol, the system can also use the public telephone network (dial-up mode) or satellite to achieve ultra-long-distance communication. Subsystems such as…

Details

00-127-755

integrated control system, integrating DCS & PLC & Field Bus; 2. Using RISC SuperScalar high-speed CPU, with super performance; Three high reliability, strict industrial application practice, more than 1000 sets of application performance in China; 4. It has good openness, flexibility and scalability; Fifth, the project is easy, the interface is friendly, and the maintenance…

Details

00-106-290

instruments, and uses the same a global database. The scale of the system is highly scalable, and a single-system supports 1 to a maximum of 100 control stations and 100 operating stations. each control The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded. The…

Details