5X0026144G01

configuration and PS The user program is downloaded to the PS CPU through diginets and the first network card. After the field bus interface card is newly installed or replaced, the required group The status information will be automatically reloaded. The configuration results and real-time process data are stored in RAM, and ram is installed…

Details

5X00226G03

controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special Redundant communication link (diginetr) to ensure information synchronization between master…

Details

5X00481G01

H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS. Industrial “field control explosion (AC800F) consists of the following components: Basic unit pm802f Power supply sa801f/sd802f o Ethernet network card ei801f/ei802f/ei803f o Fieldbus interface card fi810f/fi820f/fi830f Various accessories The main components…

Details

3A99190G01

and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the same tool…

Details

5X00105G14

modules (control algorithm subroutines), in addition to the base specified in IEC 61131 3 standard In addition to this content, many powerful and strictly tested function blocks from practical engineering applications are also expanded. Any complex control All schemes can be realized by the combination of these function blocks. The function blocks provided by the…

Details

5X00226G01

which is divided into FMS, DP and pa Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user Different transmission…

Details

5X00241G02

expanded. The hardware of the system control station is all metal enclosure, which can withstand the most Harsh industrial environment. The equipment can be installed in the cabinet or on the wall. The system complies with all current EMC standards and has CE standards Annals. Industrial “DCS system design purpose: the most economical engineering investment…

Details

5X00225G01

thus ensuring the It is universal, open and easy to use, and brings great convenience for future technology upgrading and maintenance. System engineering configuration is very convenient. The configuration language is based on ie0611313 industrial standard and provides function block diagram (FBD) and ladder diagram (LD), instruction list (IL), sequential function diagram (SFC), structured text…

Details

5X00063G01

The field controller supports various field buses such as PROFIBUS, which is the most widely used open field bus in the world Line international standard, divided into FMS, DP and PA, DP communication rate can be as high as 12MB. Can (din/is011898 standard) bus The biggest feature is its super robustness and data security. The…

Details

5X00062G01

whole plant, even The industrial “system can cope with the field equipment maintenance management and cross plant production management control applications As an important member of industrial “family, AC800F system fully embodies industrial” initiated and led by ABB in technology Information technology) a new trend. The system is divided into two levels: operation management level…