JANCD-MRY02

1990, it obtained the DQS certificate based on ISO9001 certification, EQnet quality based on ISO 9000/EN 29000 was subsequently achieved Certification. However, the Freelance 800F is more than technical excellence, I We have also spent a lot of effort in proper planning, installation and revision too This makes engineering design and maintenance faster, more economical…

Details

JANCD-GSPIO

Real-time process values ??and alarms in the system can be accessed via OPC. We also provide a C language programming interface to embed external In Windows operating system applications, it is suitable for implementing user Communicate with non-standard OPC, ie DMS-API software package. Project database All configured signals, variables and process points are in Freelance…

Details

DF9200414-A0

in the office and on site. Operator-level PC Can also be used as an engineer station. Engineer standing during system uptime Intervals can be closed without a permanent connection to the system. Freelance 800F Process Control Stage At the process control level, the Freelance 800F system can be controlled by It consists of a number…

Details

JANCD-FC860

(ST) ●Extensive function block library, user-defined function blocks can also be added Added to it, the macro library and graphic symbols can be customized for the user. Blocks can create graphics and operator panels. ●Any standard can be integrated by means of GSD file import PROFIBUS-DP and PA devices, and through user-defined pairing dialog box…

Details

JANCD-JSP11

Builder F) to configure the entire control system, including automation functions function, operator interface display and logging, and configuration of the fieldbus. equipment (PROFIBUS, FOUNDATION Fieldbus, HART, etc.) and device parameter settings. ● Automatic generation of global data between the process control station and the operator station According to communication.   For field devices, process…

Details

JANCD-MM0903

redundant configuration and non-redundant configuration. AC800F : This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2 AC800F controller. Rack mounted process station: This term is used to describe a rack-mounted type of process station. A redundant process station contains 2 rack-mounted CPUs. This…

Details

JANCD-NIO01

communication interface for users to use Fieldbus technology offers very flexible options. Each PS allows to insert 4 fieldbus interface cards (the card type can be different), Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and…

Details

JANCD-ECP02B2F

layout, due to the use of TCP/IP protocol, the system can also use the public telephone network (dial-up mode) or satellite to achieve ultra-long-distance communication. Subsystems such as PLC communicate with the Industrial” system through the ModBus protocol interface. The system also supports IEC870-5 over-control protocol. discussion. The Flash EPROM inside the PS provides more…

Details

JANCD-I0

DCS system design purpose: the most economical engineering investment, the most powerful control function. Five features of Industria1″ DCS system: 1. All-round integrated control system, integrating DCS & PLC & Field Bus; 2. Using RISC SuperScalar high-speed CPU, with super performance; Three high reliability, strict industrial application practice, more than 1000 sets of application performance…

Details

JANCD-PW02

function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions Algorithm library for energy blocks and a basic library with more than 200 graphic symbols and an extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete…

Details