DF9200471-E0

wall. System complies with all current EMC standards and is CE marked Chi. Industrial” DCS system design purpose: the most economical engineering investment, the most powerful control function. Five features of Industria1″ DCS system: 1. All-round integrated control system, integrating DCS & PLC & Field Bus; 2. Using RISC SuperScalar high-speed CPU, with super performance;…

Details

JASP-WRCA01

redundant PS. can be switched redundantly. S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its…

Details

JANCU-MSV01B

settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other Redundant basic unit pm802f) and can be plugged in and out…

Details

JANCD-MIF06

MIPS 4 MB FLASH-EPROM EEPROM,serial, 16 Kbit o Ram 8 MB (with error check and correction function, abb patent) 16 K internal cache (CPU cache RAM) Ram backup battery (matchdog, optional redundancy) Equipment internal temperature monitoring Watchdog I/0 sweeping cycle: configurable. Time required to process 1000 IL (instructions): < 1.0 ms (processing binary and 16…

Details

JANCD-IF21

to form a special Redundant communication link (diginetr) to ensure information synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and undisturbed connect the replacement worker Make. All inputs and outputs also support redundant operation. The data communication between the field process controller PS. operating station…

Details

JANCD-G5CO1B

o Open CAN -Bus,up to 1 MBd o Foundation Fieldbus H1 up to 31. 25KBd Foundation Fieldbus H2 (fast Ethernet) HART The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS. Industrial “field control explosion (AC800F) consists of the following components: Basic unit pm802f Power…

Details

JANCD-GSPI0

and play (plug & play) and can be plugged in and out with power. The field controller PS has the following features: o Flexible: it supports all international standard open fieldbus and can be mixed 4 high-speed fieldbuses can be connected at the same time (max. 12 MBD) Simple project: only use the same tool…

Details

JZNC-JAU05

61131 3 standard In addition to this content, many powerful and strictly tested function blocks from practical engineering applications are also expanded. Any complex control All schemes can be realized by the combination of these function blocks. The function blocks provided by the system mainly fall into the following categories: o Analog quantity processing o…

Details

JANCD-ECPO2

PROFIBUS is the most widely used open fieldbus international standard in the world, which is divided into FMS, DP and pa Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices. The communication among process station, operator station and engineer…

Details

JANCD-JIF10

control stations and 100 operation stations at most. Each control The station can support thousands of i/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is all metal enclosure, which can withstand the most Harsh industrial environment. The equipment can be installed in…

Details