JANCD-YBK21

redundant mode. Modular pluggable input/output modules Blocks are freely selected and used according to the type and number of system process signals. AC800F controller connects remote I/O or field device via fieldbus ready.   system communication Communication between operator level and process control level using TCP/IP Protocol system bus (based on Ethernet), you can choose…

Details

jancd-fc420

control system is divided into operator levels and process control level. The operator level contains controls for operation and display. Archiving and logging, trending and alarming functions. Controller executes open loop and closed loop control function.  Freelance 800F DigiVis Operator Level DigiVis operator stations use PC hardware, either standard commercial Business PCs can also be…

Details

DF9202142-DON

control station and the operator station According to communication.   x For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing cost and time investment in establishing data communication and interactive access. And ensure the consistency of data throughout the system. ●Provide system-wide…

Details

MEW01-1

a rack-mounted type of process station. A redundant process station contains 2 rack-mounted CPUs. This term is used to describe a single, non-redundant process station. In the investment of modern automation system, due to the hardware equipment department It only takes up less cost in the whole system, then write engineering applications The cost of…

Details

JANCD-CP06

and unplugged. The field controller PS has the following characteristics: o Flexible: supports all international standard open fieldbuses and can be mixed Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd) Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software mouth Access to all information from the field…

Details

DF9200658-C0

system also supports IEC870-5 over-control protocol. discussion. The Flash EPROM inside the PS provides more than 220 functional modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any…

Details

DF9202373-A0

controller supports Profibus, FF, ModBus, Can, etc. International standard fieldbus, Profibus is the most widely used open fieldbus international standard in the world, divided into FMS, DP and PA Level 3, DP communication rate can be as high as 12Mb. Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus…

Details

JANCD-CP07D

contains about 220 functions Algorithm library for energy blocks and a basic library with more than 200 graphic symbols and an extended library with a large number of 3D symbols. The system uses the same set of configuration tool software to complete the configuration and debugging of process level, operation level and even fieldbus instruments,…

Details

jancd-xcp02b

distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus The biggest feature is its super sturdiness and data security. The system of course also…

Details

JANCD-GCP02

interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other Redundant basic unit pm802f) and can be plugged in and out and replaced online.…

Details